PHILADELPHIA, PA —
OSHA Inspection: JENZA INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JENZA INC. in S 17TH ST AND MANTON ST, PHILADELPHIA, PA 19146 (NAICS 238170). OSHA activity number 335470589.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JENZA INC.
- Site address
- S 17TH ST AND MANTON ST
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19146
- Mailing
- 73 ASHLEY DR, FEASTERVILLE TREVOSE, PA 19053
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 F06
- Issued
- Oct 10, 2012
- Abate by
- Oct 11, 2012
- Penalty
- Initial $2,000 · Current $1,300 Reduced
General-duty citation text
29 CFR 1926.451(f)(6): The clearance between scaffolds and power lines were less than 10 feet. a) Jobsite: S 17th and Manton St, Philadelphia, PA - On or about 7/17/12, no protective coverings were placed on the triplex wire that was in close proximity to the employees. The employees, who were performing siding operations from a pump jack scaffold, were working approximately 4 feet from the triplex wire.
Recent events (2)
- — I (S) $1300
- — Z (S) $2000
1926.20 B01
- Issued
- Oct 10, 2012
- Abate by
- Dec 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.20(b)(1): The employer did not initiate and maintain an accident prevention programs as necessary to comply with this part: a) Jobsite: S 17th and Manton St, Philadelphia, PA - On or about 7/17/12, Jenza Inc. did not develop and implement an accident prevention program to help protect their employees from hazardous working conditions.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01 VII
- Issued
- Oct 10, 2012
- Abate by
- Oct 11, 2012
- Penalty
- Initial $2,800 · Current $1,300 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Jobsite: S 17th and Manton St, Philadelphia, PA - On or about 7/17/12, employees were not provided with a fall protection system while working from a pump jack scaffold. Employees were performing siding operations approximately 27 feet above ground level.
Recent events (2)
- — I (S) $1300
- — Z (S) $2800
1926.452 J02
- Issued
- Oct 10, 2012
- Abate by
- Dec 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. a) Jobsite: S 17th and Manton St, Philadelphia, PA - On or about 7/17/12, the poles of the pump jack scaffold were not braced at the bottom to prevent horizontal displacement. Employees were performing siding operations approximately 27 feet above ground level.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.454 A
- Issued
- Oct 10, 2012
- Abate by
- Dec 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work on a scaffold be trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used, and to understand the procedures to control or minimize those hazards. a) Jobsite: S 17th and Manton St, Philadelphia, PA - On or about 7/17/12, Jenza Inc. did not train their employees to recognize the hazards associated with their work while working from a pump jack scaffold.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Jenza INC.