OSHA Inspection: D & S ELECTRICAL TECHNOLOGIES, LLC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of D & S ELECTRICAL TECHNOLOGIES, LLC. in 8113 ZINNIA DR, TAMPA, FL 33619 (NAICS 238210). OSHA activity number 335477584.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D & S Electrical Technologies, LLC. for free Get an email when a new federal OSHA severe-injury report for D & S Electrical Technologies, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
8113 ZINNIA DR
City
TAMPA
State
FL
ZIP
33619
Mailing
1726 W CYPRESS STREET, TAMPA, FL 33606
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
10
Ownership type
Private (A)

4 citations on file for this inspection.

1926.405 A02 II D

Serious Gravity 10 1 instance 4 exposed
Issued
Dec 31, 2012
Penalty
Initial $4,900 · Current $4,900
29 CFR 1926.405(a)(2)(ii)(D):  Disconnecting switches or plug connectors were not installed to permit the disconnection of all ungrounded conductors of each temporary circuit:    (a) As observed on or about 08/01/2012, the original circuit branch feeding the 277 volt light fixtures used at room 305 at the Progress Village Middle School was modified as part of a remodeling project. Some light fixtures were removed and the two left that were used as temporary lighting were wired directly to breaker #5 of the Square D Panel Board AE located in adjacent building 2. On or about 07/20/12, an electrician that was pulling wires nearby sustained serious electrical shock when he came in contact with the high voltage branch.
Recent events (3)
  • · R (S) $4900
  • · C (S) $4900
  • · Z (S) $4900

1926.416 A03

Deleted Repeat Gravity 10 1 instance 4 exposed
Issued
Dec 31, 2012
Penalty
Initial $9,800 · Current $0 Reduced
29 CFR 1926.416(a)(3):  Before work began, the employer did not ascertain by inquiry, direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work could bring any person, tool, or machine into pysical or electrical contact with the electric power circuit.    (a) As observed on or about 08/01/2012, the original circuit branch feeding the 277 volt light fixtures used at room 305 at the Progress Village Middle School was modified as part of a remodeling project. Some light fixtures were removed and two were used as temporary lighting. Verification of the installation workmanship was not conducted to ensure the electrical continuity of the metal flexible conduit of one of the light fixtures. An electrician that was pulling wires nearby sustained serious electrical shock when he made contact with the energized branch.    The D&S Electrical Technologies was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1926.416(a)(3), which was contained in OSHA inspection number 314912569, citation number 1, item number 1 and was affirmed as a final order on 10/14/2010, with respect to a workplace located at  Seffner, FL. 29 CFR 1926.403(h):  Each service, feeder, and branch circuit was not legibly marked at its disconnecting means or overcurrent device to indicate its purpose, nor located and arranged so that the purpose was evident:    (a) Panel CLA (120/208 V) located on the mechanical room behind room # 305 of building 6 at Progress Village Middle School was wired and energized on 07/21/2012. On 07/24/2012 and on 08/01/2012 the panel was observed energized and not marked.
Recent events (3)
  • · R (O) $1250
  • · C (R) $9800
  • · Z (R) $9800

1926.405 A01 I

Other-than-serious 1 instance 4 exposed
Issued
Dec 31, 2012
Abate by
Jul 24, 2012
Penalty
Initial $4,900 · Current $1,250 Reduced
29 CFR 1926.405(a)(1)(i):  Metal raceways, cable armor, and other metal enclosures for conductors were not metallically joined together into a continuous electric conductor and so connected to all boxes, fittings, and cabinets as to provide effective electrical continuity:    (a) As observed on or about 08/01/2012, the original circuit branch feeding the 277 volt light fixtures used at room 305 at the Progress Village Middle School was modified as part of a remodeling project. Some light fixtures were removed and the two left were used as temporary lighting. A flexible conduit feeding one of the fixtures was not mechanically connected to the junction box creating a break in the path to ground. On or about 07/20/12, an electrician that was pulling wires nearby sustained serious electrical shock when he came in contact with the high voltage branch.
Recent events (3)
  • · R (O) $1250
  • · C (S) $4900
  • · Z (S) $4900

1926.417 A

Other-than-serious 3 instances 1 exposed
Issued
Dec 31, 2012
Penalty
Initial $4,900 · Current $1,250 Reduced
29 CFR 1926.417(a):  Controls that were to be deactivated during the course of work on energized or de-energized equipment or circuits were not tagged:    (a) As observed on or about 08/10/12, lockout tagout procedures were not followed when removing the 277 volts light fixtures used as temporary lighting from the lab lecture room # 301, 302, and 303 as part of the remodeling of the Progress Village Middle School.
Recent events (3)
  • · R (O) $1250
  • · C (S) $4900
  • · Z (S) $4900

View D & S Electrical Technologies, LLC.'s full OSHA safety record →