OSHA Inspection: ACCESS DEMOLITION CONTRACTING INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ACCESS DEMOLITION CONTRACTING INC in 1075 THOMAS JEFFERSON ST NW, WASHINGTON, DC 20007 (NAICS 236220). OSHA activity number 335482980.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Access Demolition Contracting INC for free Get an email when a new federal OSHA severe-injury report for Access Demolition Contracting INC is published. One employer, no account, unsubscribe in one click.
Site address
1075 THOMAS JEFFERSON ST NW
City
WASHINGTON
State
DC
ZIP
20007
Mailing
3437 9TH STREET, BALTIMORE, MD 21225
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
25
Ownership type
Private (A)

4 citations on file for this inspection.

1926.403 B02

Serious Gravity 1 4 instances 3 exposed
Issued
Sep 20, 2012
Penalty
Initial $1,200 · Current $780 Reduced
29 CFR 1926.403(b)(2):     Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.    a) On or about July 30, 2012; at the first floor; the employees were using power strips/taps to provide power to portable equipment such as but not limited to sprayers, fans and the battery charging stations; either directly or through portable extension cords. The power strips/taps are not designed for outdoor or construction site use.
Recent events (2)
  • · I (S) $780
  • · Z (S) $1200

1926.404 B01 II

Serious Gravity 5 4 instances 4 exposed
Issued
Sep 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(ii):     Ground-fault circuit interrupters. All 120-volt, single-phase 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.    a) On or about July 30, 2012; at the first floor; the employees were using power tools such as but not limited to sprayers and saws that were plugged in directly or by portable extension cords into outlets that were not equipped with a ground fault circuit interrupter.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.404 F06

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6):     Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.    a) On or about July 30, 2012; at the first floor; the employees were using portable extension cord which had the ground pin missing. The extension cord was being used to power the sprayer used in the process.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.405 B02

Serious Gravity 1 4 instances 3 exposed
Issued
Sep 20, 2012
Penalty
Initial $1,200 · Current $780 Reduced
29 CFR 1926.405(b)(2):     Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.    a) On or about July 30, 2012; at the first floor; the employees were using power tools such as but not limited to sprayers and saws that were plugged in directly or by portable extension cords into outlets that were not properly guarded with a face plate.
Recent events (2)
  • · I (S) $780
  • · Z (S) $1200

View Access Demolition Contracting INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335482980.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.