MOUNT VERNON, NY —
OSHA Inspection: TOTAL PLASTICS INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TOTAL PLASTICS INC. in 590 FRANKLIN AVE., MOUNT VERNON, NY 10550 (NAICS 326199). OSHA activity number 335487989.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TOTAL PLASTICS INC.
- Site address
- 590 FRANKLIN AVE.
- City
- MOUNT VERNON
- State
- NY
- ZIP
- 10550
- Mailing
- 590 FRANKLIN AVE., MOUNT VERNON, NY 10550
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 8
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.36 G02
- Issued
- Jan 17, 2013
- Abate by
- Jan 24, 2013
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.36(g)(2): An exit access must be at least 28 inches (71.1 cm) wide at all points. Where there is only one exit access leading to an exit or exit discharge, the width of the exit and exit discharge must be at least equal to the width of the exit access: Location; Exit door west side of the warehouse a) The exit route leading to the west side of the ware house was reduced by stored materials to 14 inches wide; on or about 7/23/2012
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1910.37 A03
- Issued
- Jan 17, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level. Location; Exit door west side of the warehouse a) The exit door leading to the west side of the ware house was obstructed by a cart; on or about 7/23/12
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.110 F02 I
- Issued
- Jan 17, 2013
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.110(f)(2)(i): Containers in storage shall be located so as to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons. Location; Loading dock, west side of the warehouse a) Two propane thanks were located in a high traffic area used by the forklift operators, the tanks were exposed to a physical damage. On or about; 12/04/12
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1910.176 B
- Issued
- Jan 17, 2013
- Abate by
- Feb 21, 2013
- Penalty
- Initial $2,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.176(b): Secure storage. Storage of material shall not create a hazard. Bags, containers, bundles, etc., stored in tiers shall be stacked, blocked, interlocked and limited in height so that they are stable and secure against sliding or collapse: Location; Loading dock a) Employees working on the loading dock were exposed to struck by hazards from wood pallets that were not secured and stored in an unstable manner; on or about 12/04/12 b) Employees working on the loading dock were exposed to struck by hazards from a 3/4 inch plywood sheets that were on top of a rack. The plywood sheets were not secured and stored in a stable manner; on or about 12/04/12
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
1910.212 A02
- Issued
- Jan 17, 2013
- Abate by
- Feb 1, 2013
- Penalty
- Initial $2,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.212(a)(2): General requirements for machine guards. Guards shall be affixed to the machine where possible and secured elsewhere if for any reason attachment to the machine is not possible. The guard shall be such that it does not offer an accident hazard in itself. Location; Finishing area, warehouse a) Employees were exposed to coming into contact with the unguarded portion of a Ryobi Compound Miter saw blade while cutting pieces of plastic. The retractable guard was not functioning; on or about 12/04/12
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
More inspections at Total Plastics INC.
View Total Plastics INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335487989.