Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GARCIA ROOFING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GARCIA ROOFING, INC. in 876 BLOSSOM, PROSPECT HEIGHTS, IL 60070 (NAICS 238160). OSHA activity number 335491593.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Garcia Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for Garcia Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
876 BLOSSOM
City
PROSPECT HEIGHTS
State
IL
ZIP
60070
Mailing
4860 W. NEWPORT, CHICAGO, IL 60641
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
8
Ownership type
A

7 citations on file for this inspection.

1926.100 A

Serious Gravity 5 3 instances 3 exposed
Issued
Aug 30, 2012
Abate by
Aug 31, 2012
Penalty
Initial $1,760 · Current $750 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    a) Employees were exposed to head injury from falling or flying objects while working below a hoist area without the benefit of head protection.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $750
  • — Z (S) $1760

1926.501 B01

Serious Gravity 10 12 instances 4 exposed
Issued
Aug 30, 2012
Abate by
Aug 31, 2012
Penalty
Initial $3,080 · Current $1,300 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:    a) Employees were exposed to the hazard of falling approximately 30 feet while disposing of roofing materials and debris at the roof edge where fall protection had not been provided.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1300
  • — Z (S) $3080

1926.501 B03

Serious Gravity 10 12 instances 2 exposed
Issued
Aug 30, 2012
Abate by
Aug 31, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(3): Each employee in a hoist area was not protected from falling 6 feet (1.8m) or more to lower levels by guardrail systems or personal fall arrest systems:    a) Employees were exposed to the hazard of falling approximately 30 feet while operating a material hoist to raise materials and equipment to the edge of the roof deck.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 F04

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 30, 2012
Abate by
Aug 31, 2012
Penalty
Initial $3,080 · Current $1,300 Reduced
29 CFR 1926.502(f)(4):  Mechanical equipment on roofs was used or stored only in areas where employees were not protected by a warning line system, guardrail system, or personal fall arrest system:    a) Employees were exposed to the hazard of falling approximately 30 feet while operating mechanical equipment without the benefit of fall protection.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1300
  • — Z (S) $3080

1926.552 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 30, 2012
Abate by
Aug 31, 2012
Penalty
Initial $2,200 · Current $950 Reduced
29 CFR 1926.552(a)(1): The employer did not comply with the manufacturer's specifications and limitations applicable to the operation of all hoists and elevators. Where manufacturer's specifications are not available, the limitations assigned to the equipment were not based on the determinations of a professional engineer competent in the field:    a) A manually operated material handling host at the roof edge was counterweighted with rolled roofing materials and not with approved counterweights.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $950
  • — Z (S) $2200

1926.501 B10

Repeat Gravity 10 8 instances 8 exposed
Issued
Aug 30, 2012
Abate by
Aug 31, 2012
Penalty
Initial $15,400 · Current $6,500 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system:    a) Employees were exposed to the hazard of falling approximately 30 feet while performing roofing activities without the use of fall protection or a warning line system and safety monitoring system.    Garcia Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501 (b)(10) which was contained in OSHA inspection number 311248462, citation 2, item 1, issued on March 20, 2008, and became final order on or about March 28, 2008.    Garcia Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501 (b)(10) which was contained in OSHA inspection number 311247167, citation 1, item 1, issued on December 4, 2007, and became final order on or about December 20, 2007.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (R) $6500
  • — Z (R) $15400

1926.503 B01

Other-than-serious 8 instances 8 exposed
Issued
Aug 30, 2012
Abate by
Oct 30, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer:    a) Garcia Roofing, Inc. did not prepare written certification records related to employee fall protection training.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Garcia Roofing, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335491593.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.