Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: AAA PROFESSIONAL LAWN CARE, INC.

Fatality or catastrophe inspection · Safety discipline

On , OSHA opened a fatality or catastrophe safety inspection of AAA PROFESSIONAL LAWN CARE, INC. in 5 COUNTRY VIEW DRIVE, JOHNSTON, RI 02919 (NAICS 561730). OSHA activity number 335499844.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AAA Professional Lawn Care, INC. for free Get an email when a new federal OSHA severe-injury report for AAA Professional Lawn Care, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5 COUNTRY VIEW DRIVE
City
JOHNSTON
State
RI
ZIP
02919
Mailing
17 DEER VIEW ROAD, JOHNSTON, RI 02919
Inspection type
Fatality or catastrophe (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561730
Employees
4
Ownership type
Private (A)

7 citations on file for this inspection.

1910.332 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 6, 2012
Abate by
May 23, 2013
Penalty
Initial $7,000 · Current $2,148 Reduced
29 CFR 1910.332(b)(1):     Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:  (a) Jobsite: Employees working near overhead power lines were not familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments, on or about 7-30-12.
Recent events (3)
  • · F (S) $2148
  • · C (S) $7000
  • · Z (S) $7000

1910.333 C03

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 6, 2012
Abate by
May 23, 2013
Penalty
Initial $7,000 · Current $2,142 Reduced
29 CFR 1910.333(c)(3):     When work was to be performed near overhead lines, the lines were not deenergized and grounded, nor were other protective measures provided before work was started:  (a) Jobsite: An employee was performing tree trimming near an energized overhead line, and the line was not deenergized and grounded, nor were other protective measures provided before work was started, for a jobsite located in Johnston RI on or about 7-30-12.
Recent events (3)
  • · F (S) $2142
  • · C (S) $7000
  • · Z (S) $7000

1910.333 C03 I A

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 6, 2012
Abate by
May 23, 2013
Penalty
Initial $7,000 · Current $2,142 Reduced
29 CFR 1910.333(c)(3)(i)(A):     When an unqualified person is working in an elevated position near overhead lines, the location shall be such that the person and the longest conductive object he or she may contact cannot come closer to any unguarded, energized overhead line than the distances specified in 1910.333(c)(3)(i)(A)(1) & (2):  (a) Jobsite: An employee was performing tree trimming near an energized 7, 200 volt overhead line, and the aluminum long reach pruner being used by the employee came closer to the unguarded, energized overhead line than the distance of 10 feet as specified in 1910.333(c)(3)(i)(A)(1), for a jobsite located in Johnston RI on or about 7-30-12.
Recent events (3)
  • · F (S) $2142
  • · C (S) $7000
  • · Z (S) $7000

1910.333 C06

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 6, 2012
Abate by
May 23, 2013
Penalty
Initial $7,000 · Current $2,142 Reduced
29 CFR 1910.333(c)(6):     Where an employee is required to handle long dimensional conductive objects in areas with exposed live parts, the employer did not institute work practices (such as the use of insulation, guarding, and material handling techniques) to minimize the hazards:  (a) Jobsite: An employee was performing tree trimming near an energized 7, 200 volt overhead line and using an aluminum long reach pruner, and the employer did not institute work practices to minimize the hazards, for a jobsite located in Johnston RI on or about 7-30-12.
Recent events (3)
  • · F (S) $2142
  • · C (S) $7000
  • · Z (S) $7000

1910.335 A01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 6, 2012
Abate by
May 23, 2013
Penalty
Initial $7,000 · Current $2,142 Reduced
29 CFR 1910.335(a)(1)(i):     Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:  (a) Jobsite: An employee was performing tree trimming near an energized 7, 200 volt overhead line and was not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed, such as but not limited to, electrical protective gloves, for a jobsite located in Johnston RI on or about 7-30-12.
Recent events (3)
  • · F (S) $2142
  • · C (S) $7000
  • · Z (S) $7000

1910.335 A02 I

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 6, 2012
Abate by
May 23, 2013
Penalty
Initial $7,000 · Current $2,142 Reduced
29 CFR 1910.335(a)(2)(i):     When working near exposed energized conductors or circuit parts, each employee did not use insulated tools or handling equipment when the tools or handling equipment might have made contact with such conductors or parts:  (a) Jobsite: An employee was performing tree trimming near an energized 7, 200 volt overhead line and was not provided with and did not use an insulated pruner, for a jobsite located in Johnston RI on or about 7-30-12.
Recent events (3)
  • · F (S) $2142
  • · C (S) $7000
  • · Z (S) $7000

1910.335 A02 II

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 6, 2012
Abate by
May 23, 2013
Penalty
Initial $7,000 · Current $2,142 Reduced
29 CFR 1910.335(a)(2)(ii):     Protective shields, protective barriers, or insulating materials were not used to protect each employee from shock, burns, or other electrically related injuries while that employee was working near exposed energized parts which might be accidentally contacted or where dangerous electric heating or arcing might occur.  (a) Jobsite: An employee was performing tree trimming near an energized 7, 200 volt overhead line and was not provided with and did not use Protective shields, protective barriers, or insulating materials appropriate to protect each employee from shock, burns, or other electrically related injuries, for a jobsite located in Johnston RI on or about 7-30-12.
Recent events (3)
  • · F (S) $2142
  • · C (S) $7000
  • · Z (S) $7000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335499844.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.