CALDWELL, ID —
OSHA Inspection: ZAMCO TECHNOLOGIES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ZAMCO TECHNOLOGIES, INC. in 21991 MIDDLETON ROAD, CALDWELL, ID 83605 (NAICS 332812). OSHA activity number 335501789.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ZAMCO TECHNOLOGIES, INC.
- Site address
- 21991 MIDDLETON ROAD
- City
- CALDWELL
- State
- ID
- ZIP
- 83605
- Mailing
- 21991 MIDDLETON ROAD, CALDWELL, ID 83605
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332812
- Employees
- 7
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.134 C
- Issued
- Sep 4, 2012
- Abate by
- Oct 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use: (a) Establishment: on 7/27/2012 and at times prior thereto, the employer did not have a written respiratory protection program for employees required to wear tight sealing face masks including the Moldex 7000 series respirators. NOTE: Abatement certification IS required for this item.
Recent events (1)
- — Z (O) $0
1910.134 F01
- Issued
- Sep 4, 2012
- Abate by
- Oct 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a) Establishment: on 7/27/2012 and at times prior thereto, employees were not required to complete an appropriate fit test for Moldex 7000 series respirators. NOTE: Abatement certification IS required for this item.
Recent events (1)
- — Z (O) $0
1910.134 G01 I A
- Issued
- Sep 4, 2012
- Abate by
- Oct 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face: (a) Paint booth: on 7/27/2012 and at times prior thereto, two workers wearing the Moldex 7000 series respirator had facial hair that compromised the mask's tight-fitting seal while applying powder coat. NOTE: Abatement certification IS NOT required for this item.
Recent events (1)
- — Z (O) $0
1910.305 B02 I
- Issued
- Sep 4, 2012
- Abate by
- Oct 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: (a) West end of north wall: on 7/27/2012 and at times prior thereto, an electrical outlet box at 90 inches (7 feet, 6 inches) from the floor did not have a cover installed. NOTE: Abatement certification IS required for this item.
Recent events (1)
- — Z (O) $0
1910.1200 E01
- Issued
- Sep 4, 2012
- Abate by
- Oct 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) Establishment: on 7/27/2012 and at times prior thereto, the employer did not have a written program that advised workers of exposures to and protection from toxic and/or hazardous substances present in the bulk Cardinal powder coating, including titanium dioxide and triglycidyl isocyanurate. NOTE: Abatement certification IS required for this item.
Recent events (1)
- — Z (O) $0
More inspections at Zamco Technologies, INC.
View Zamco Technologies, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332812)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335501789.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.