Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ELEMENT ENGINEERING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ELEMENT ENGINEERING in SIDEWALKS PROJECT BETWEEN BUILDINGS 362 AND 363 CAMP PARKS, DUBLIN, CA 94568 (NAICS 237310). OSHA activity number 335510384.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Element Engineering — free Get an email when a new federal OSHA severe-injury report for Element Engineering is published. One employer, no account, unsubscribe in one click.
Establishment
ELEMENT ENGINEERING
Site address
SIDEWALKS PROJECT BETWEEN BUILDINGS 362 AND 363 CAMP PARKS
City
DUBLIN
State
CA
ZIP
94568
Mailing
10 WHITTIINGTON DRIVE, NEWCASTLE, CA 95658
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237310
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.701 B

Other-than-serious 1 instance 4 exposed
Issued
Aug 13, 2012
Abate by
Aug 27, 2012
Penalty
Initial $900 · Current $500 Reduced
29 CFR 1926.701(b): Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, was not guarded to eliminate the hazard of impalement:    (a) Between buildings 362 and 363 on or about July 31, 2012, dozens of ? inch diameter steel stakes, that protruded vertically from about 3 to 8 inches above the concrete formwork, were not guarded to eliminate the hazard of impalement.  Employees were next to and over the steel stakes to place and level concrete for new sidewalks.
Recent events (2)
  • — I (O) $500
  • — Z (S) $900

1926.404 B01 I

Other-than-serious 1 instance 3 exposed
Issued
Aug 13, 2012
Abate by
Aug 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(i): The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors:    (a)  Between buildings 362 and 363 on or about July 31, 2012, there was no assured equipment grounding conductor program or ground-fault circuit-interrupter to protect employees that used an extension cord used to supply power to a 110 VAC Skilsaw circular saw.  The saw was used to cut wood for formwork for the concrete sidewalks.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.404 F06

Other-than-serious 1 instance 3 exposed
Issued
Aug 13, 2012
Abate by
Aug 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, and enclosures was not permanent and continuous:    (a)  Between buildings 362 and 363 on or about July 31, 2012, the grounding pin was not in place on an extension cord used to supply power to a 110 VAC Skilsaw circular saw.  The saw was used to cut wood for formwork for the concrete sidewalks.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.405 A02 II I

Other-than-serious 1 instance 3 exposed
Issued
Aug 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables shall be protected from damage:    (a)  At building 363 on or about July 31, 2012, a flexible cord was not protected from damage as it was pinched between the gasket and threshold at an exterior door and pinched between frame and door at an exterior door.  The extension cord was used to supply power to a 110 VAC Skilsaw circular saw.  The saw was used to cut wood for formwork for the concrete sidewalks.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Element Engineering's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335510384.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.