WOOSTER, OH ·
OSHA Inspection: PSC GARN TRUCKING
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PSC GARN TRUCKING in 877 OLD WEST LINCOLN WAY, WOOSTER, OH 44691 (NAICS 484121). OSHA activity number 335510418.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PSC GARN TRUCKING
- Site address
- 877 OLD WEST LINCOLN WAY
- City
- WOOSTER
- State
- OH
- ZIP
- 44691
- Mailing
- 877 OLD WEST LINCOLN WAY, WOOSTER, OH 44691
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 484121
- Employees
- 45
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.157 G02
- Issued
- Sep 11, 2012
- Abate by
- Sep 25, 2012
- Penalty
- Initial $3,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: The employer did not train employees on the use of portable fire extinguishers for those employees expected to fight incipient stage fires. NOTE: The employer may exercise one of the following options: 1) Provide portable fire extinguishers as specified in 29 CFR 1910.157(c)(1), meet the distribution requirements per 29 CFR 1910.157(d) (75 to the nearest extinguisher for Class A fires and 50 to the nearest extinguisher for Class B fires), and provide training and education for all employees in the use of such equipment and the hazards associated with incipient stage fire fighting as required in 29 CFR 1910.157(g). The other sections of 29 CFR 1910.157 also apply. 2) Provide extinguishers as specified in 29 CFR 1910.157(c) (1), designate certain employees to be the only employees authorized to use such equipment and require all other employees to immediately evacuate upon the sounding of the fire alarm, establish this in writing in an emergency action plan as outlined in 29 CFR 1910.38(c) and train/educate designated employees per 1910.157(g). Utilizing this option exempts the employer from distribution requirements of 29 CFR 1910.157(d). 3) Establish a written fire safety policy which requires the immediate and total evacuation of employees from the workplace upon the sounding of a fire alarm signal. This policy includes an emergency action plan and a fire prevention plan as specified in 29 CFR 1910.38(a) and (b). Utilizing this option exempts the employer from the requirements of 1910.157 to include the need for providing portable fire equipment unless a specific standard requires that a portable fire extinguisher be provided (such as those requirements in 29 CFR 1910.106/107 relating to use/storage of flammable/combustible liquids). If extinguishers are provided but not intended for employee use, 29 CFR 1910.157(a) and (f) are still applicable (inspection, maintenance and testing of equipment).
Recent events (2)
- · I (O) $1000
- · Z (S) $3000
1910.178 L01 I
- Issued
- Sep 11, 2012
- Abate by
- Oct 11, 2012
- Penalty
- Initial $4,000 · Current $4,000
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not provide training and evaluation for powered industrial truck operators: On or before August 8, 2012, employees who were required to operate a powered industrial truck have not received training. Training shall consist of a combination of formal instruction (e.g., lecture, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace.
Recent events (2)
- · I (S) $4000
- · Z (S) $4000
1910.212 A01
- Issued
- Sep 11, 2012
- Abate by
- Sep 25, 2012
- Penalty
- Initial $5,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about August 1, 2012 saws in the service bay area were not adequately guarded; A. Saw guards were not adjusted adequately to guard unused portions of the blade on the Grizzly band saw. The right side contained a 2 1/2" unused exposure area. B. The chop saw was not equipped with a guard arranged to prevent accidental contact with the saw including but limited to behind and underneath the saw.
Recent events (2)
- · I (S) $0
- · Z (S) $5000
1910.303 F02
- Issued
- Sep 11, 2012
- Abate by
- Sep 21, 2012
- Penalty
- Initial $3,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: At the time of inspection the circuit control panel located on the southwest wall did not contain the proper labelling to describe the equipment or energy source corresponding to each circuit breaker or switch. The panel controlled the circuitry for the outside truck heaters.
Recent events (2)
- · I (S) $1500
- · Z (S) $3000
1910.305 G02 III
- Issued
- Sep 11, 2012
- Abate by
- Sep 25, 2012
- Penalty
- Initial $3,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws On or about August 1, 2012, the electrical cord supplying power for the chop saw located in the service bay shop area, was not equipped with a strain relief.
Recent events (2)
- · I (O) $1000
- · Z (S) $3000
1910.334 A03 I
- Issued
- Sep 11, 2012
- Abate by
- Sep 25, 2012
- Penalty
- Initial $3,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.334(a)(3)(i): A flexible cord used with the type of ground equipment did not contain an electrical equipment grounding conductor. On or about August 1, 2012, the flexible cord on the band saw located in the service bay area did not contain a ground conductor plug as needed.
Recent events (2)
- · I (S) $0
- · Z (S) $3000
1910.37 A01
- Issued
- Sep 11, 2012
- Abate by
- Sep 12, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(1): The evacuation route contained hazardous and or flammable chemicals. On or about August 1, 2012, the rear exit egress route from the service bay area contained flammable materials such as but not limited to gasoline and propane cylinders.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.1200 H01
- Issued
- Sep 11, 2012
- Abate by
- Sep 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: The employer did not provide employees with information and training on hazardous chemicals such as but not limited to; oils, lubricants, propane, and coolant solutions.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 484121)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335510418.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.