LITTLE NECK, NY —
OSHA Inspection: A & J Z CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of A & J Z CONSTRUCTION, INC. in 52-68 DOUGLASTON PARKWASY, LITTLE NECK, NY 11362 (NAICS 236115). OSHA activity number 335511986.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A & J Z CONSTRUCTION, INC.
- Site address
- 52-68 DOUGLASTON PARKWASY
- City
- LITTLE NECK
- State
- NY
- ZIP
- 11362
- Mailing
- 39-15 MAIN STREET SUITE 308, FLUSHING, NY 11354
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.405 G02 III
- Issued
- Jan 17, 2013
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap: a) On or before July 30, 2012-Job Site at 52-68 Douglaston Parkway Douglaston NY 11362 Employees exposed flexible cord sets that have been spliced and not retained their original insulation exposing live electric. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED PURSUANT TO CFR 1903.19.
Recent events (2)
- — I (O) $0
- — Z (S) $2000
1926.451 B01
- Issued
- Jan 17, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights: a) On or before July 30, 2012-Job Site at 52-68 Douglaston Parkway Douglaston NY 11362 Employee working on two 6-inch planks at 16-feet 8-inches above the next lower level on tubular welded frame scaffold leaving 33-inches un-planked. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED PURSUANT TO CFR 1903.19.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.451 E01
- Issued
- Jan 17, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: a) On or before July 30, 2012-Job Site at 52-68 Douglaston Parkway Douglaston NY 11362 Employee climbs out onto scaffodl then climb 4-feet to the working that is 16-feet above the next lower level. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED PURSUANT TO CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Jan 17, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or before July 30, 2012-Job Site at 52-68 Douglaston Parkway Douglaston NY 11362 Employee working on a roof 25-feet above the next lower level repairing the chimney. WRITTEN ABATEMENT DOCUMENTATION IS NOT REQUIRED PURSUANT TO CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
More inspections at A & J Z Construction, INC.
View A & J Z Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236115)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335511986.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.