Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: NEBRASKA ELECTRONICS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NEBRASKA ELECTRONICS, INC. in 12202 CARY CIRCLE, LA VISTA, NE 68128 (NAICS 334418). OSHA activity number 335513982.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nebraska Electronics, INC. for free Get an email when a new federal OSHA severe-injury report for Nebraska Electronics, INC. is published. One employer, no account, unsubscribe in one click.
Site address
12202 CARY CIRCLE
City
LA VISTA
State
NE
ZIP
68128
Mailing
12202 CARY CIRCLE, LA VISTA, NE 68128
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334418
Employees
50
Ownership type
Private (A)

5 citations on file for this inspection.

1910.178 G02

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 12, 2012
Abate by
Sep 27, 2012
Penalty
Initial $2,380 · Current $1,666 Reduced
29 CFR 1910.178(g)(2):     Facilities were not provided for flushing and neutralizing spilled electrolyte, for fire protection, for protecting charging apparatus from damage by trucks, and for adequate ventilation for dispersal of fumes from gassing batteries.    Maintenance area: A battery charger unit used to charge the forklift was not protected from damage from forklifts.
Recent events (2)
  • · I (S) $1666
  • · Z (S) $2380

1910.212 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 12, 2012
Abate by
Sep 27, 2012
Penalty
Initial $1,785 · Current $1,249 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding shall were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, rotating parts, flying chips and sparks.     North wall of production area-None of the drill presses were properly guarded.
Recent events (2)
  • · I (S) $1249
  • · Z (S) $1785

1910.303 B08 I

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 12, 2012
Abate by
Sep 27, 2012
Penalty
Initial $2,380 · Current $1,666 Reduced
29 CFR 1910.303(b)(8)(i):     Electric equipment was not firmly secured to the surface on which it is mounted.    North wall and soldering machine area- Receptacle/knock-out boxes were not firmly secured to any surface.
Recent events (2)
  • · I (S) $1666
  • · Z (S) $2380

1910.305 G01 IV D

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 12, 2012
Abate by
Oct 19, 2012
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1910.305(g)(1)(iv)(D):     Flexible cords were used where attached to building surfaces.     North wall-Entension cords powering equipemnt such as but not limited to drill presses were attached to metal conduit and other parts of the building.
Recent events (2)
  • · I (S) $1960
  • · Z (S) $2800

1910.305 G02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 12, 2012
Abate by
Sep 27, 2012
Penalty
Initial $2,380 · Current $1,666 Reduced
29 CFR 1910.305(g)(2)(ii):     Flexible cords were not used in continuous lengths without a splice or tap.     Work bench north wall-Two flexible cords were spliced and taped together.