OSHA Inspection: PARKER HOUSE SERVICES INC
Other inspection · Health discipline
At a glance
On , OSHA opened an other health inspection of PARKER HOUSE SERVICES INC in 463 7TH AVE, NEW YORK, NY 10018 (NAICS 562910). OSHA activity number 335525788.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PARKER HOUSE SERVICES INC
- Site address
- 463 7TH AVE
- City
- NEW YORK
- State
- NY
- ZIP
- 10018
- Mailing
- 32 CHAUCER ST, HARTSDALE, NY 10530
What kind of inspection was it?
- Inspection type
- Other (L)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562910
- Employees
- 4
- Ownership type
- Private (A)
Citations
9 citations on file for this inspection.
1910.134 C01
- Issued
- Oct 30, 2012
- Abate by
- Nov 21, 2012
- Penalty
- Initial $2,000 · Current $2,000
9020
General-duty citation text
29 CFR 1910.134(c)(1): The employer did not develop and implement a written respiratory protection program with worksite specific procedures and elements for required respirator use as referenced by 1926.1101 (h)(2)(i) a) In basement storage room 1, The employer did not develop a written respiratory protection program for employees who are required wear North 7700 half face respirators when removing 4% asbestos floor tiles. Condition noted on 05/03/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER CFR 1903.19.
Recent events (1)
- · Z (S) $2000
1910.134 E01
- Issued
- Oct 30, 2012
- Abate by
- Nov 21, 2012
- Penalty
- Initial $0 · Current $0
9020
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator as referenced by 1926.1101 (h)(2)(i). a) basement storage room 1 The employer did not medically evaluate employees who are required to wear North 7700 half face respirators when removing 4% asbestos floor tiles. Condition noted on or about 05/03/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER CFR 1903.19.
Recent events (1)
- · Z (S) $0
1910.134 F01
- Issued
- Oct 30, 2012
- Abate by
- Nov 21, 2012
- Penalty
- Initial $0 · Current $0
9020
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employees using a tight-fitting facepiece respirator pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) as stated in this paragraph as referenced by 1926.1101 (h)(2)(i) a) basement storage room 1, The employer did not fit test employees who are required to wear North 7700 half face respirators when removing $% asbestos floor tiles. Condition noted on or about 05/03/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER CFR 1903.19.
Recent events (1)
- · Z (S) $0
1910.134 K
- Issued
- Oct 30, 2012
- Abate by
- Nov 21, 2012
- Penalty
- Initial $0 · Current $0
9020
General-duty citation text
29 CFR 1910.134(k): The employer did not provide effective training annually for employees who are required to use a respirator as referenced by 1926.1101 (h)(2)(i) a) Basement storage room 1, The employer did not provide training for employees who are required to wear North 7700 half face respirators when removing 4% asbestos floor tiles. Condition noted on or about 05/03/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER CFR 1903.19.
Recent events (1)
- · Z (S) $0
1926.1101 E01
- Issued
- Oct 30, 2012
- Abate by
- Nov 21, 2012
- Penalty
- Initial $2,000 · Current $2,000
9020
General-duty citation text
29 CFR 1926.1101(e)(1): All Class I, II and III asbestos work was not conducted within regulated areas. a) In basement storage room 1, The employer did not ensure that employees who are required to perform Type II asbestos removal did so in a regulated area. Floor tested contained 4% asbestos. Condition noted on or about 05/03/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER CFR 1903.19.
Recent events (1)
- · Z (S) $2000
1926.1101 E06
- Issued
- Oct 30, 2012
- Abate by
- Nov 21, 2012
- Penalty
- Initial $2,000 · Current $2,000
9020
General-duty citation text
29 CFR 1926.1101(e)(6): Competent Persons. The employer did not ensure that all asbestos work performed within regulated areas is supervised by a competent person, as defined in paragraph (b) of this section. The duties of the competent person are set out in paragraph (o) of this section. a) In basement storage room 1, Employer did not ensure that asbestos containing floor tile that was removed was supervised by a competent person. Floor tested contained 4% asbestos. Condition noted on or about 05/03/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER CFR 1903.19.
Recent events (1)
- · Z (S) $2000
1926.1101 F02 I
- Issued
- Oct 30, 2012
- Abate by
- Jan 14, 2013
- Penalty
- Initial $2,000 · Current $2,000
9020
General-duty citation text
29 CFR 1926.1101(f)(2)(i): Each employer who had a workplace or work operation covered by this standard did not ensure that a "competent person" conducted an exposure assessment immediately before or at the initiation of the operation to ascertain expected exposures during that operation or workplace. a) In basement storage room 1, The employer did not perform an initial assessment for employees who are required perform Type II asbestos work when removing floor tiles that contained 4% asbestos. Condition noted on or about 05/03/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER CFR 1903.19.
Recent events (1)
- · Z (S) $2000
1926.1101 G01 III
- Issued
- Oct 30, 2012
- Abate by
- Nov 21, 2012
- Penalty
- Initial $2,000 · Current $2,000
9020
General-duty citation text
29 CFR 1926.1101(g)(1)(iii): Prompt clean-up and disposal of wastes and debris contaminated with asbestos was not palaced in leak-tight containers except in roofing operations, where the procedures specified in paragraph (g)(8)(ii) of this section apply. a) In basement storage room 1, The employer did not place asbestos containing floor tile in a sealed leak-tight container. Condition noted on or about 05/03/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER CFR 1903.19.
Recent events (1)
- · Z (S) $2000
1926.1101 O01
- Issued
- Oct 30, 2012
- Abate by
- Nov 21, 2012
- Penalty
- Initial $2,000 · Current $2,000
9020
General-duty citation text
29 CFR 1926.1101(o)(1): The employer did not designate a competent person on construction worksites, having the qualifications and authorities for ensuring worker safety and health required by 29 CFR 1926.1101(C), General Safety and Health Provisions for Construction 29 CFR 1926.20 through 29 CFR 1926.32: a) In basement storage room 1, Employer did not ensure that asbestos containing floor tile that was removed in a regulated area was supervised by a competent person. Floor tested contained 4% asbestos. Condition noted on or about 05/03/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER CFR 1903.19.
Recent events (1)
- · Z (S) $2000
More inspections at Parker House Services INC
View Parker House Services INC's full OSHA safety record →
More inspections in this industry (NAICS 562910)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335525788.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.