BROCKTON, MA —
OSHA Inspection: BURNS BUILDERS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BURNS BUILDERS in 16 ARDSLEY CIRCLE, BROCKTON, MA 02302 (NAICS 238130). OSHA activity number 335545398.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BURNS BUILDERS
- Site address
- 16 ARDSLEY CIRCLE
- City
- BROCKTON
- State
- MA
- ZIP
- 02302
- Mailing
- 85 OAK STREET, AVON, MA 02322
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 2
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B13
- Issued
- Aug 14, 2012
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502. Jobsite: Approximately nine second floor window openings were unguarded exposing employees to a fall hazard of approximately 15 feet.
Recent events (1)
- — Z (S) $2000
1926.503 A01
- Issued
- Aug 14, 2012
- Abate by
- Sep 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: Employees have not been adequately trained in fall hazards and fall protection.
Recent events (1)
- — Z (S) $0
1926.404 B01 II
- Issued
- Aug 14, 2012
- Penalty
- Initial $1,360 · Current $1,360
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection. Jobsite: The orange electrical extension cord ran through a large puddle. The extension cord was used to provide power to the circular saw used on the second floor. The extension cord's receptacle lacked a ground fault circuit interrupter.
Recent events (1)
- — Z (S) $1360
1926.403 D01
- Issued
- Aug 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(d)(1): Electric equipment was not firmly secured to the surface on which it was mounted: Jobsite: back yard The extension cord receptacle was not secured to the piece of lumber on which it rested. The extension cord provided power to the second floor circular saw.
Recent events (1)
- — Z (S) $0
More inspections at Burns Builders
View Burns Builders's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335545398.