GAINESVILLE, FL ·
OSHA Inspection: WHITTON ROOFING CO.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WHITTON ROOFING CO. in 418 NW 18TH STREET, GAINESVILLE, FL 32601 (NAICS 238160). OSHA activity number 335548186.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WHITTON ROOFING CO.
- Site address
- 418 NW 18TH STREET
- City
- GAINESVILLE
- State
- FL
- ZIP
- 32601
- Mailing
- P.O. BOX 775, MELROSE, FL 32666
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 9
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.102 A01
- Issued
- Sep 20, 2012
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about August 3, 2012, all employees using nail guns did not wear safety glasses, exposing themselves to eye injuries. Abatement Certification and Documentation are not required
Recent events (2)
- · I (S) $720
- · Z (S) $1200
1926.501 B13
- Issued
- Sep 20, 2012
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b): a. On or about August 3, 2012, employees installing roofing shingles on a 5:12 pitch roof were not protected from falling 8 feet by the use of a guardrail system, safety net system, personal fall arrest system or any other type fall protection. Abatement Certification and Documentation are not required