EDMOND, OK ·
OSHA Inspection: D&E ROOFING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of D&E ROOFING in 16120 ZANTERA CREEK, EDMOND, OK 73013 (NAICS 238160). OSHA activity number 335558607.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- D&E ROOFING
- Site address
- 16120 ZANTERA CREEK
- City
- EDMOND
- State
- OK
- ZIP
- 73013
- Mailing
- 1225 PREIS LINE APT#1, GODFREY, IL 62035
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Dec 14, 2012
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. On or about August 2, 2012, the employer did not ensure employees working from a roof with unprotected sides and edges were in use of fall protection exposing the employees to a fall hazard of more than 6 feet to the ground below.
Recent events (1)
- · Z (S) $2000
1926.1053 B01
- Issued
- Dec 14, 2012
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access. On or about August 2, 2012, the employer did not ensure the side rails of an extension ladder extended at least 3 feet above the landing exposing employees to a fall hazard.
Recent events (1)
- · Z (S) $2000
More inspections at D&E Roofing
View D&E Roofing's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335558607.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.