SAN JUAN, PR —
OSHA Inspection: INTERNATIONAL SHIPPING AGENCY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of INTERNATIONAL SHIPPING AGENCY, INC. in SEA STAR TERMINAL SAN JUAN, SAN JUAN, PR 00902 (NAICS 488320). OSHA activity number 335558698.
Where did this inspection happen?
- Establishment
- INTERNATIONAL SHIPPING AGENCY, INC.
- Site address
- SEA STAR TERMINAL SAN JUAN
- City
- SAN JUAN
- State
- PR
- ZIP
- 00902
- Mailing
- PO BOX 9022748 SAN JUAN, SAN JUAN, PR 00902
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488320
- Employees
- 50
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.101 B
- Issued
- Abate by
- Penalty
- Initial $5000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.101(b): Before using cylinder, be sure it is properly supported to prevent it from being knocked over. a) On or about 5/25/12, at Maintence Mechanics Shop, Sea Star terminal, Puerto Nuevo, PR: Employees worked nearby and oxygene compress gas cylinder which was left standing near a wall and was not secured. NOTE: Certification of abatement is not required for this citation item as abatement was documented by the compliance safety and health officer during the inspection.
Recent events (2)
- — I (O) $1000
- — Z (S) $5000
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $6000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a. On or about 05/25/12, at the mechanic shop, Sea Star, Puerto Nuevo: Employees were exposed to injurious corrosive materials such as Brake Part Cleaner, Antifreeze/Coolant and other fluids and oils used and/or handled during the heavy equipment maintenance repairs. Suitable facilities for quick drenching or flushing of the eyes and body were not working properly within the work area for immediate emergency use. NOTE: Certification of abatement is not required for this citation item as abatement was documented by the compliance safety and health officer during the inspection
Recent events (2)
- — I (O) $1000
- — Z (S) $6000
1910.157 C04
- Issued
- Abate by
- Penalty
- Initial $3000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition: a. On or about 05/25/12, at the Mechanic Maintenance Shop, Sea Star, Puerto Nuevo: Portable fire extinguiishers were not maintained charged and operable condition. Note: Certification and documentation of abatement must be submitted for this citation item as required by 29 CFR 1903.19(c) and (d), respectively.
Recent events (2)
- — I (O) $1000
- — Z (S) $3000
1917.43 C05
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $5000.00 Reduced
General-duty citation text
29 CFR 1917.43(c)(5): Safety devices on powered industrial trucks were removed or made inoperative. a. On or about 05/25/12, Sea Star terminal, San Juan PR. Employees were operating Kalmar and Hyster 360 top loaders and Hustler trucks without fire extinguishers, brake lights, and audible horn / back-up alarm system. Note: Certification and documentation of abatement must be submitted for this citation item as required by 29 CFR 1903.19(c) and (d), respectively.
Recent events (2)
- — I (S) $5000
- — Z (S) $7000
1917.111 A
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1917.111(a): The structural integrity of docks, wharves, piers, terminals and/or working surfaces was not maintained. On or about 05/25/12, Sea Star terminal, Puerto Nuevo, San Juan, PR. Employees engaged in the stevedoring operations were exposed to struck by, caught by and fall hazards as evidenced by the by the terrain conditions on several areas at the marine terminal. Several holes and unleveled terrain were observed where hustler trucks (brutes), with or without trailers, were moving while performing stevedoring operations. Note: Certification and Documentation of abatement must be submitted for this citations item as required by 29 CFR 1903.19(c) and (d), respectively
Recent events (2)
- — I (S) $0
- — Z (S) $7000
1910.157 E03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: a. On or about 05/25/12, at the Mechanic Maintenance Shop, Sea Star, Puerto Nuevo: Portable fire extinguishers were not subjected to an annual maintenance check. Note: Certification and documentation of abatement must be submitted for this citation item as required by 29 CFR 1903.19(c) and (d), respectively.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at INTERNATIONAL SHIPPING AGENCY, INC.
SAN JUAN, PR—2012-05-25 00:00:00
INTERNATIONAL SHIPPING AGENCY, INC.
SAN JUAN, PR—2009-10-02 00:00:00
INTERNATIONAL SHIPPING AGENCY, INC
SAN JUAN, PR—2006-08-03 00:00:00
INTERNATIONAL SHIPPING AGENCY, INC.
SAN JUAN, PR—2006-06-02 00:00:00
INTERNATIONAL SHIPPING AGENCY, INC.
SAN JUAN, PR—2004-08-11 00:00:00
INTERNATIONAL SHIPPING AGENCY, INC.
View INTERNATIONAL SHIPPING AGENCY, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 488320)
MARATHON, FL—2026-07-14 00:00:00
DISCOUNT ROCK & SAND, INC.
RIVIERA BEACH, FL—2026-07-07 00:00:00
PORT CONTRACTORS SOUTHEAST, LLC
JACKSONVILLE, FL—2026-07-01 00:00:00
CROWLEY LINER SERVICES
SEATTLE, WA—2026-06-30 00:00:00
WA317991873 - SSA TERMINALS LLC
TERMINAL ISLAND, CA—2026-06-10 00:00:00
YUSEN TERMINALS LLC
More inspections in PR
SAN JUAN, PR—2026-07-16 00:00:00
U.S. DEPARTMENT OF AGRICULTURE-FOREST SERVICE
PONCE, PR—2026-07-15 00:00:00
CENTROS SOR ISOLINA FERRE INC
PONCE, PR—2026-07-15 00:00:00
FC CONSTRUCTION LLC
PONCE, PR—2026-07-15 00:00:00
HECTOR M. RIVERA
SAN JUAN, PR—2026-07-15 00:00:00
MUNICIPIO DE SAN JUAN
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335558698.