PARK RIDGE, IL —
OSHA Inspection: PRO-TECH ROOFING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PRO-TECH ROOFING, INC. in 1050 BUSSEE HIGHWAY, PARK RIDGE, IL 60068 (NAICS 238160). OSHA activity number 335569588.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PRO-TECH ROOFING, INC.
- Site address
- 1050 BUSSEE HIGHWAY
- City
- PARK RIDGE
- State
- IL
- ZIP
- 60068
- Mailing
- 216 S. GRACELEND, DES PLAINES, IL 60016
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.416 A01
- Issued
- Aug 31, 2012
- Abate by
- Sep 4, 2012
- Penalty
- Initial $2,200 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by deenergizing and grounding the circuits or effectively guarding the circuits by insulation or other means: a) Employees were exposed to electrical hazards where roofing work was conducted at the location of a service drop power line having a voltage rating of 120/240 volts. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1000
- — Z (S) $2200
1926.501 B01
- Issued
- Aug 31, 2012
- Abate by
- Sep 4, 2012
- Penalty
- Initial $3,080 · Current $1,320 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) Employees were exposed to the hazard of falling approximately 16 feet while disposing of roofing materials and debris at the roof edge where fall protection had not been provided. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1320
- — Z (S) $3080
1926.501 B03
- Issued
- Aug 31, 2012
- Abate by
- Sep 4, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(b)(3): Each employee in a hoist area was not protected from falling 6 feet (1.8m) or more to lower levels by guardrail systems or personal fall arrest systems: a) Employees were exposed to the hazard of falling approximately 16 feet while operating a material hoist at the edge of the roof deck. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B04 I
- Issued
- Aug 31, 2012
- Abate by
- Sep 4, 2012
- Penalty
- Initial $3,080 · Current $1,320 Reduced
General-duty citation text
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes: a) Employees were exposed to the hazard of falling approximately 16 feet through unprotected skylights located throughout to roof deck work area. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1320
- — Z (S) $3080
1926.502 F04
- Issued
- Aug 31, 2012
- Abate by
- Sep 4, 2012
- Penalty
- Initial $3,080 · Current $1,540 Reduced
General-duty citation text
29 CFR 1926.502(f)(4): Mechanical equipment on roofs was used or stored only in areas where employees were not protected by a warning line system, guardrail system, or personal fall arrest system: a) Employees were exposed to the hazard of falling approximately 16 feet while operating mechanical equipment without the benefit of fall protection. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1540
- — Z (S) $3080
1926.552 A01
- Issued
- Aug 31, 2012
- Abate by
- Sep 4, 2012
- Penalty
- Initial $2,200 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.552(a)(1): The employer did not comply with the manufacturer's specifications and limitations applicable to the operation of all hoists and elevators. Where manufacturer's specifications are not available, the limitations assigned to the equipment were not based on the determinations of a professional engineer competent in the field: a) A manually operated material handling host at the roof edge was counterweighted with rolled roofing materials and not with approved counterweights. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1000
- — Z (S) $2200
1926.501 B10
- Issued
- Aug 31, 2012
- Abate by
- Sep 4, 2012
- Penalty
- Initial $6,160 · Current $3,820 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. NOTE: On roofs less than 50 feet wide safety monitoring alone can be used: a) Employees were exposed to the hazard of falling approximately 16 feet while performing roofing activities without the use of fall protection or a safety monitoring system. Pro-Tech Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501 (b)(10) which was contained in OSHA inspection number 311374136, citation 1, item 1, issued on May 29, 2008, and became final order on or about June 17, 2008. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $3820
- — Z (R) $6160
More inspections at Pro-Tech Roofing, INC.
View Pro-Tech Roofing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335569588.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.