PORT ORANGE, FL —
OSHA Inspection: CENTRAL FLORIDA CONSTRUCTION WALLS, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of CENTRAL FLORIDA CONSTRUCTION WALLS, INC. in 907 TAYLOR AVE., PORT ORANGE, FL 32127 (NAICS 238140). OSHA activity number 335582383.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CENTRAL FLORIDA CONSTRUCTION WALLS, INC.
- Site address
- 907 TAYLOR AVE.
- City
- PORT ORANGE
- State
- FL
- ZIP
- 32127
- Mailing
- 5923 BAMBOO DR., ORLANDO, FL 32807
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.100 A
- Issued
- Oct 31, 2012
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. On or about July 24, 2012, at the southwest of the building located at 907 Taylor Ave, Port Orange, FL, an employee working for Central Florida Construction Walls, Inc., was not protected by a hardhat while hammering a lath metal strap above his head, exposing himself to head injuries.
Recent events (3)
- — A (O) $1200
- — I (O) $0
- — Z (S) $1200
1926.451 E01
- Issued
- Oct 31, 2012
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1926.451(e)(1): A means of access for scaffold platforms more than 2 feet (0.6 m) above or below a point of access, such as portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used. a. On or about July 24, 2012, at the southwest of the building located at 907 Taylor Ave, Port Orange, FL, employees working for Central Florida Construction Walls, Inc., were climbing the frame of the scaffold to gain access to the roof, exposing themselves to an 8.3 feet fall hazard. Central Florida Construction Walls, Inc., was previously cited for a violation of this safety and health standard or its equivalent standard 29 CFR 1926.451(e)(1) which was contained in inspection number 316517914, citation 1, item 3, issued on March 28, 2012, with respect to a work place located at 11731 Colonial Dr., Orlando, FL 32826. The final order date was May 17, 2012.
Recent events (3)
- — A (R) $2400
- — I (R) $2000
- — Z (R) $2400
1926.501 B10
- Issued
- Oct 31, 2012
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and fuardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. a. On or about July 24, 2012, at the southwest of the building located at 907 Taylor Ave, Port Orange, FL, employees working for Central Florida Construction Walls, Inc., were doing stucco work on a 4:12 pitch roof and not being protected by a guardrail system, safety net or personal fall arrest system, exposing themselves to an 8.3 feet fall hazard. Central Florida Construction Walls, Inc., was previously cited for a violation of this safety and health standard or its equivalent standard 29 CFR 1926.501(b)(10) which was contained in inspection number 316517914, citation 1, item 6, issued on March 28, 2012, with respect to a work place located at 11731 Colonial Dr., Orlando, FL 32826. The final order date was May 17, 2012.
Recent events (3)
- — A (R) $2400
- — I (R) $2000
- — Z (R) $2400
1926.454 B02
- Issued
- Oct 31, 2012
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.454(b)(2): The employer did not have each employee who was involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the correct procedures for erecting, disassembling, moving, operating, repairing, inspecting, and maintaining the type of scaffold in question. a. On or about July 24, 2012, at the southwest of the building located at 907 Taylor Ave, Port Orange, FL, employees working for Central Florida Construction Walls, Inc., assembled a tubular frame scaffold without been trained by a competent person in the correct procedures for erecting, disassembling, operating, repairing, inspecting, and maintaining, exposing themselves to fall hazards.
Recent events (3)
- — A (S) $1200
- — I (S) $1000
- — Z (S) $1200
More inspections at Central Florida Construction Walls, INC.
View Central Florida Construction Walls, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335582383.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.