OSHA Inspection: KAMPEN ELECTRIC INC

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of KAMPEN ELECTRIC INC in 4929 YORK, METAIRIE, LA 70001 (NAICS 238210). OSHA activity number 335589784.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kampen Electric INC for free Get an email when a new federal OSHA severe-injury report for Kampen Electric INC is published. One employer, no account, unsubscribe in one click.
Establishment
KAMPEN ELECTRIC INC
Site address
4929 YORK
City
METAIRIE
State
LA
ZIP
70001
Mailing
1020 JUSTIN RD, METAIRIE, LA 70001
Inspection type
Programmed Related (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
2
Ownership type
Private (A)

4 citations on file for this inspection.

1910.146 C05 II B

Other-than-serious 1 instance 2 exposed
Issued
Dec 13, 2012
Abate by
Dec 18, 2012
Penalty
Initial $1,080 · Current $0 Reduced
29 CFR 1910.146(c)(5)(ii)(B): When entrance covers are removed, the opening shall be promptly guarded by a railing, temporary cover, or other temporary barrier that will prevent an accidental fall through the opening and that will protect each employee working in the space from foreign objects entering the space.    On or about 08/06/2012, the employer did not ensure that when the expanded metal cover was removed from the opening to a crawl space beneath the building, barricades were not erected to prevent anyone falling into the openong. The opening measured 24"x36" and was approx. 36" deep at the opening
Recent events (2)
  • · I (O) $0
  • · Z (S) $1080

1910.146 C05 II C

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 13, 2012
Abate by
Dec 19, 2012
Penalty
Initial $2,520 · Current $1,260 Reduced
29 CFR 1910.146(c)(5)(ii)(C): Before an employee enters the space, the internal atmosphere shall be tested, with a calibrated direct-reading instrument, for oxygen content, for flammable gases and vapors, and for potential toxic air contaminants, in that order. Any employee who enters the space, or that employee's authorized representative, shall be provided an opportunity to observe the pre-entry testing required by this paragraph.    On or about 08/06/2012, the employer did not ensure that air monitoring of the crawl space beneath the structure was conducted prior to employees entering. The crawl space beneath the structure was approx 100 ft long with two side crawl spaces that were perpendicular to it. The crawll space was 4 ft square and contained a substantial amount of standing water inside.
Recent events (2)
  • · I (S) $1260
  • · Z (S) $2520

1910.146 D09

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 13, 2012
Abate by
Dec 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.146(d)(9): Develop and implement procedures for summoning rescue and emergency services, for rescuing entrants from permit spaces, for providing necessary emergency services to rescued employees, and for preventing unauthorized personnel from attempting a rescue;    On or about 08/06/2012the emplpoyer did not develop procedures to rescue employees working in a confined space. Two employees were working in the confined space beneath the structure, without any means of rescue and retrieval of injured employees.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.404 A02

Deleted Serious Gravity 1 1 instance 15 exposed
Issued
Dec 13, 2012
Abate by
Dec 19, 2012
Penalty
Initial $1,080 · Current $0 Reduced
29 CFR 1926.404(a)(2): Polarity of connections. No grounded conductor shall be attached to any terminal or lead so as to reverse designated polarity.    On or about 08/06/2012, the employer did not ensure that the outlets on the temporary power pole at the rear of the structure, were wired correctly. Outlets were found to have two "hot" terminals unstead of  a hot and neutral. This exposed site personnel to electric shock hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $1080

View Kampen Electric INC's full OSHA safety record →