WASHINGTON, DC ·
OSHA Inspection: KIM MYUNG BOK
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KIM MYUNG BOK in 2334 KING PL NW, WASHINGTON, DC 20009 (NAICS 236115). OSHA activity number 335594982.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KIM MYUNG BOK
- Site address
- 2334 KING PL NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20009
- Mailing
- 9913 PORTSMOUTH RD, MANASSAS, VA 20109
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 2
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1926.451 G01
- Issued
- Oct 23, 2012
- Penalty
- Initial $2,800 · Current $1,800 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part. a) On or about August 6, 2012; front of residential home; employees were working on a Ladder-jack scaffold without a personal fall arrest system in place to protect them from falling 20 feet to ground level
Recent events (2)
- · I (S) $1800
- · Z (S) $2800
1926.451 E01
- Issued
- Oct 23, 2012
- Penalty
- Initial $2,800 · Current $1,800 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access. a) On or about August 6, 2012; front of residential home; employees were accessing the ladder-jack scaffold platform by reaching for an extension ladder that is located next to the scaffold; thus exposing the employee to a 20 foot fall to ground level.
Recent events (2)
- · I (S) $1800
- · Z (S) $2800
1926.451 B05 II
- Issued
- Oct 23, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(5)(ii): Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end. a) On or about August 6, 2012; at the front of the residential home left side of platform, the ladder-jack scaffold platform extended 32 inches over its support exposing the platform to tipping hazard.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.1053 B04
- Issued
- Oct 23, 2012
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders shall be used only for the purpose for which they were designed. a) On or about August 6, 2012; front of residential home; employees were working on a ladder-jack scaffold which an extension ladder was used in place of the plank.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
More inspections in this industry (NAICS 236115)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335594982.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.