WASHINGTON, DC —
OSHA Inspection: APOSTLE CONSTRUCTION INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of APOSTLE CONSTRUCTION INC. in 1917 BLADENSBURG ROAD NE HOLIDAY INN EXPRESS, WASHINGTON, DC 20002 (NAICS 238160). OSHA activity number 335602389.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- APOSTLE CONSTRUCTION INC.
- Site address
- 1917 BLADENSBURG ROAD NE HOLIDAY INN EXPRESS
- City
- WASHINGTON
- State
- DC
- ZIP
- 20002
- Mailing
- 716 NAYLOR MILL RD, SALISBURY, MD 21801
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.501 B10
- Issued
- Aug 30, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system. a) Holiday Inn Hotel Roof, North Face - Roofers were observed working on a low slope roof at 60 feet above ground and were not protected against fall hazards, on or about 08/01/12.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.503 B01
- Issued
- Aug 30, 2012
- Abate by
- Sep 29, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer shall verify compliance with paragraph (a) of this section by preparing a written certification record. The written certification record shall contain the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. If the employer relies on training conducted by another employer or completed prior to the effective date of this section, the certification record shall indicate the date the employer determined the prior training was adequate rather than the date of actual training. a) Job Site - A written certification record of fall protection training given to each employee exposed to fall hazards was not provided. ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 D06 I
- Issued
- Aug 30, 2012
- Abate by
- Aug 31, 2012
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.502(d)(6)(i): Snaphooks of the locking type were not designed to be hooked directly to the webbing, rope, or wire rope. a) Holiday Inn Hotel, South Face of Roof - A roofer was observed using a Personal Fall Arrest System (PFAS) for fall protection and the snaphook of the shock absorbing lanyard was wrapped around a 4 inch metal antenna pole and back to its webbing, on or about 08/01/12. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.502 D06 II
- Issued
- Aug 30, 2012
- Abate by
- Aug 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(6)(ii): Snaphooks of the locking type were not designed to be hooked to each other. a) Holiday Inn Hotel, South Face of Roof - A roofer was observed using a Personal Fall Arrest System (PFAS) for fall protection and the snaphook of the rope line was attached to the snaphook of a shock absorbing lanyard, on or about 08/01/12. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 D15
- Issued
- Aug 30, 2012
- Abate by
- Aug 31, 2012
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person. a) Holiday Inn Hotel, North Face of Roof - Roofers were observed attaching shingles to a roof and as part of their Personal Fall Arrest System (PFAS) their rope line was attached to a vent pipe located on the roof, on or about 08/01/12. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.1053 B01
- Issued
- Aug 30, 2012
- Abate by
- Aug 31, 2012
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where a portable ladder was used for access to an upper level landing surface and the ladders length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. a) Holiday Inn Hotel, South Side of Roof - Roofers were exposed to a fall hazard as they used a 4 foot Werner portable step ladder to access/exit a roof and the top of the ladder measured 2 feet below the landing surface, on or about 08/01/12. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1926.1053 B13
- Issued
- Aug 30, 2012
- Abate by
- Aug 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step. a) Holiday Inn Hotel, South Face of Building - Roofers were exposed to a fall hazard as they used the top step of a 4 foot Werner portable step ladder to gain access to a roof, on or about 08/01/12. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238160)