OSHA Inspection: CARDEN EXTERIORS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CARDEN EXTERIORS INC. in 5013 W. WINNEMAC AVE., CHICAGO, IL 60656 (NAICS 238160). OSHA activity number 335621389.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Carden Exteriors INC. for free Get an email when a new federal OSHA severe-injury report for Carden Exteriors INC. is published. One employer, no account, unsubscribe in one click.
Site address
5013 W. WINNEMAC AVE.
City
CHICAGO
State
IL
ZIP
60656
Mailing
4817 W. BERENICE, CHICAGO, IL 60641
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
Private (A)

4 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 4 exposed
Issued
Sep 11, 2012
Penalty
Initial $3,080 · Current $2,156 Reduced
29 CFR 1926.501(b)(13):  Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:    a)  Employees performing roofing work were exposed to fall hazards of approximately 21.1 feet.    No abatement certification or documentation is required for this item.
Recent events (2)
  • · I (S) $2156
  • · Z (S) $3080

1926.502 D15

Serious Gravity 10 1 instance 4 exposed
Issued
Sep 11, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(15):  Anchorages used for attachment of personal fall arrest equipment shall be independent of any anchorage being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee attached, or shall be designed, installed, and used as follows:    a)  Anchorages being used for attachment of personal fall arrest equipment were not installed so that they would be capable of supporting at least 5,000 pounds per employee attached.    No abatement certification or documentation is required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 11, 2012
Penalty
Initial $2,200 · Current $1,540 Reduced
29 CFR 1926.1053(b)(1):  When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder.  In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.     a)  Employees were using an extension ladder which did not extend 3 feet above the upper landing being accessed.     No abatement certification or documentation is required for this item.
Recent events (2)
  • · I (S) $1540
  • · Z (S) $2200

1926.405 G01 III

Other-than-serious 1 instance 6 exposed
Issued
Sep 11, 2012
Abate by
Sep 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(1)(iii):  Flexible cords and cables were:  (A) Used as a substitute for the fixed wiring of a structure; (B) Run though holes in walls, ceilings, or floors; (C) Run through doorways, windows, or similar openings; (D) Attached to building surfaces; or (E) Concealed behind building walls, ceilings, or floors:    a)  Flexible cords and cables were run though windows.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Carden Exteriors INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335621389.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.