Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A & A WHEELER MANUFACTURING INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of A & A WHEELER MANUFACTURING INC. in 300 CALEF HIGHWAY., LEE, NH 03824 (NAICS 321114). OSHA activity number 335629382.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A & a Wheeler Manufacturing INC. — free Get an email when a new federal OSHA severe-injury report for A & a Wheeler Manufacturing INC. is published. One employer, no account, unsubscribe in one click.
Site address
300 CALEF HIGHWAY.
City
LEE
State
NH
ZIP
03824
Mailing
300 CALEF HIGHWAY., LEE, NH 03824
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321114
Employees
22
Ownership type
A

7 citations on file for this inspection.

1910.22 A01

Other-than-serious 2 instances 9 exposed
Issued
Sep 18, 2012
Abate by
Sep 19, 2012
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1910.22(a)(1):  All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.      a.  Site - Housekeeping was inadequate in that saw dust, wood scrap and other debris was allowed to accumulate on the shop floors creating slip and fall hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1600

1910.23 C01

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 18, 2012
Abate by
Sep 19, 2012
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.23(c)(1):  Every open-sided floor or platform 4 feet or more above adjacent floor or ground level was not guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides and railings were not provided as required:      a.  Parts Building - Guardrails were not provided at the overhead storage area to prevent falls.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2000

1910.23 D01

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 18, 2012
Abate by
Sep 19, 2012
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.23(d)(1):  Every flight of stairs having four or more risers was not equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section, the width of the stair to be measured clear of all obstructions except handrails:    a.  Site Parts Building - Handrails were not provided for the access staircase leading to overhead storage area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1910.242 B

Serious Gravity 5 4 instances 5 exposed
Issued
Sep 18, 2012
Abate by
Sep 19, 2012
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.242(b):  Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:      a.  Site - Compressed air utilized for cleaning purposes at employees workstations was at 92 PSI.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.243 A01 I

Serious Gravity 10 2 instances 1 exposed
Issued
Sep 18, 2012
Abate by
Sep 19, 2012
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.243(a)(1)(i):  Portable power driven circular saw(s) having a blade diameter greater than two inches were not equipped with guard(s) below the base plate or shoe which automatically and instantly returned to the covering position when the tool was withdrawn from the work:      a.  Site Parts Building - Two Porter-Cable (PC15CSL) 7 1/4-Inch circular saws in use were not guarded which cause and could cause amputations.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $2800

1910.243 A02 I

Serious Gravity 10 2 instances 1 exposed
Issued
Sep 18, 2012
Abate by
Sep 19, 2012
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.243(a)(2)(i):  Constant pressure switch(es) or control(s) which would shut off the power when pressure is released were not provided on a hand held power circular saw having a blade diameter greater than 2 inches:       a.  Site homemade tablesaw - Switch controls for two Porter-Cable (PC15CSL) 7 1/4-Inch circular saws were zip tied thus thus eliminating their operability.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $2800

1910.157 C01

Other-than-serious 1 instance 1 exposed
Issued
Sep 18, 2012
Abate by
Sep 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1):  Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:      a.  Site - A portable fire extinguisher was blocked by stored materials.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View A & a Wheeler Manufacturing INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335629382.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.