Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: KENNAMETAL, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KENNAMETAL, INC in 599 NORTHGATE CIRCLE, NEW CASTLE, PA 16105 (NAICS 331221). OSHA activity number 335633996.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kennametal, INC for free Get an email when a new federal OSHA severe-injury report for Kennametal, INC is published. One employer, no account, unsubscribe in one click.
Establishment
KENNAMETAL, INC
Site address
599 NORTHGATE CIRCLE
City
NEW CASTLE
State
PA
ZIP
16105
Mailing
599 NORTHGATE CIRCLE, NEW CASTLE, PA 16105
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331221
Employees
1850
Ownership type
Private (A)

2 citations on file for this inspection.

1910.253 B04 III

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 5, 2012
Abate by
Oct 29, 2012
Penalty
Initial $3,000 · Current $1,800 Reduced
29 CFR 1910.253(b)(4)(iii):     Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least      A.)  Kennametal Inc.; Northgate Circle, Aerospace - On or about 7/26/12, oxygen and propane cylinders were being stored on a cart in the basement.
Recent events (2)
  • · I (S) $1800
  • · Z (S) $3000

1910.147 C06 I C

Other-than-serious 1 instance 2 exposed
Issued
Oct 5, 2012
Abate by
Oct 29, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i)(C):     Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected:        A.)  Kennametal Inc., Northgate Circle - On or about 7/26/12, the periodic inspection only included a physical walk-around review of energy isolation points.  The periodic inspection did not audit employees and/or review the authorized employees responsibilities under the energy control procedures. Employees performed servicing and maintenance work on machines/equipment that included, but was not limited to the crush AVS6X10 #2, the wheelabrator W-1, and the chrome furnace #7.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Kennametal, INC's full OSHA safety record →