WASHINGTON, DC —
OSHA Inspection: ENCORE CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ENCORE CONSTRUCTION, INC. in 5252 WISCONSIN AVENUE, NW, WASHINGTON, DC 20001 (NAICS 236220). OSHA activity number 335646394.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ENCORE CONSTRUCTION, INC.
- Site address
- 5252 WISCONSIN AVENUE, NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20001
- Mailing
- 2014 RENARD COURT SUITE J, ANNAPOLIS, MD 21401
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 1
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B10
- Issued
- Nov 7, 2012
- Penalty
- Initial $2,400 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels and 50-feet (15.25 m) wide or less, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and personal fall arrest system, or warning line system and safety monitor system, or safety monitor system alone: a) Exterior Front - Employees were observed standing on a low sloped roof while attaching sheet metal trim around a window, and exposed to a 10 feet, 9 inch fall hazard.
Recent events (2)
- — I (S) $1200
- — Z (S) $2400
1926.1053 B01
- Issued
- Nov 7, 2012
- Penalty
- Initial $2,400 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) Exterior Front - Roofers were observed using a portable step ladder to gain access to a roof surface, and the top step was 2 ft, below the landing surface, exposing the roofers to a 10 feet fall hazard.
Recent events (2)
- — I (S) $1200
- — Z (S) $2400
1926.1053 B13
- Issued
- Nov 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) Exterior Front - Roofers were observed standing on the top step of an 8 feet portable step ladder to gain access to a roof landing, and exposed to an 8 ft, fall to a concrete sidewalk below.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Encore Construction, INC.
View Encore Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335646394.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.