Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VETERANS AFFAIRS: PUGET SOUND HEALTH CARE SYSTEM

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of VETERANS AFFAIRS: PUGET SOUND HEALTH CARE SYSTEM in 1660 S. COLUMBIAN WAY, SEATTLE, WA 98108 (NAICS 622110). OSHA activity number 335655031.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Veterans Affairs: Puget Sound Health Care System — free Get an email when a new federal OSHA severe-injury report for Veterans Affairs: Puget Sound Health Care System is published. One employer, no account, unsubscribe in one click.
Site address
1660 S. COLUMBIAN WAY
City
SEATTLE
State
WA
ZIP
98108
Mailing
1660 S. COLUMBIAN WAY PSHS (S-00-SAFE), SEATTLE, WA 98108
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
622110
Employees
1800
Ownership type
D

16 citations on file for this inspection.

1910.22 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 14, 2012
Abate by
Jan 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1):     On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate.    A)     At the Seattle VA hospital shop, a loft above the lock shop was used for storage, but there was no load rating posted.
Recent events (1)
  • — Z (S) $0

1910.23 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 14, 2012
Abate by
Jan 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.23(c)(1):     Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent):    A)     The storage loft above the lock shop at the Seattle Veteran's hospital did not have guardrails erected to protect employees from falling.
Recent events (1)
  • — Z (S) $0

1910.37 B01

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 14, 2012
Abate by
Jan 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(1):     Each exit route was not adequately lighted so that an employee with normal vision can see along the exit route.    A)     In Room 719 of the research section located at the Seattle VA hospital, the door was designed to be locked from both sides, and there was no emergency lighting in the room to illuminate the emergency exit button that was located adjacent to the door.
Recent events (1)
  • — Z (S) $0

1910.176 B

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 14, 2012
Abate by
Jan 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.176(b):     Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse:    A)     In the warehouse section of the Seattle VA Hospital, there were several storage racks that were damaged to the point that many of the members were showing signs of serious structural fatigue.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 14, 2012
Abate by
Jan 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    A)   In the maintenance shop for the research section of the Seattle VA hospital, there was a metal lathe that did not have a chuck guard.
Recent events (1)
  • — Z (S) $0

1910.215 A02

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 14, 2012
Abate by
Jan 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(2):     The safety guard did not cover the spindle end, nut, and flange projections:    A)     In the research maintenance shop, at the Seattle VA Hospital, there was a bench grinder that was missing the spindle guard.
Recent events (1)
  • — Z (S) $0

1910.215 A04

Serious Gravity 5 2 instances 4 exposed
Issued
Nov 14, 2012
Abate by
Dec 11, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4):     Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    A)     In research shop, and the pump room, there were bench grinders that did not have properly adjusted work rests.
Recent events (1)
  • — Z (S) $0

1910.215 B09

Serious Gravity 1 3 instances 5 exposed
Issued
Nov 14, 2012
Abate by
Dec 11, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9):     The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    A)     In shops at the Seattle VA Hospital, the tongue guards for bench grinders were adjusted to have a larger gap than 1/4 of an inch from the guard to the wheel's surface.
Recent events (1)
  • — Z (S) $0

1910.215 D03

Serious Gravity 1 4 instances 5 exposed
Issued
Nov 14, 2012
Abate by
Dec 11, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.215(d)(3):     The contact surface(s) of wheel(s), blotter(s) or flange(s) on grinding machine(s) were not flat and free or foreign matter:    A)      Grinders used in shops at the Seattle VA hospital had grinding wheels that were contaminated with foreign material, and in some cases grooved.
Recent events (1)
  • — Z (S) $0

1910.303 G01 I A

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(i)(A):     For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening whwere they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:    A)     At the Seattle VA hospital in room 606, access to the breaker panels for class III lasers was blocked with stored items.
Recent events (1)
  • — Z (S) $0

1910.305 B01 I

Serious Gravity 1 1 instance 10 exposed
Issued
Nov 14, 2012
Abate by
Dec 11, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(i):     Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed:    A)     In the loading bay of the warehouse, at the Seattle VA hospital, there was an electrical outlet box that had come loose from its anchor points int the wall, and had been pulled out so that wires were visible.
Recent events (1)
  • — Z (S) $0

1910.305 C04

Serious Gravity 1 1 instance 7 exposed
Issued
Nov 14, 2012
Abate by
Dec 11, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(c)(4):     Snap switches mounted in boxes did not have faceplates installed so as to completely cover the opening and seat against the finished surface:    A) In the pump room at the Seattle VA Hospital, there was a light switch that did not have a cover plate.
Recent events (1)
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 1 1 instance 4 exposed
Issued
Nov 14, 2012
Abate by
Dec 11, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i):     Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:    A)     An electrical outlet in building 11 room 5 did not have a faceplate.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Other-than-serious 1 instance 12 exposed
Issued
Nov 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2):     Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    A) in the food preparation area of the Biomed repair lab, employees had a microwave oven plugged into a low voltage relocatable power tap.
Recent events (1)
  • — Z (O) $0

1910.1096 E02

Other-than-serious 2 instances 5 exposed
Issued
Nov 14, 2012
Abate by
Jan 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1096(e)(2):     The radiation area(s) were not conspicuously posted with a sign or signs bearing the radiation caution symbol described in 29 CFR 1910.1096(e)(1) and the words:  "Caution, Radiation Area":    A) In the spinal cord injury area at the Seattle VA Hospital, there was a room with an x-ray machine that did not have a caution sign posted on the entrance.    B) in the bronchology clinic at the Seattle VA hospital, there was a room with an x-ray machine, that  did not have a caution sign posted on the entrance to the room.
Recent events (1)
  • — Z (O) $0

1910.1026 D01

Other-than-serious 1 instance 2 exposed
Issued
Nov 14, 2012
Abate by
Jan 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1026(d)(1):     The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI):    A)     In the welding shop at the Seattle VA hospital, employees perform welding operations on stainless steel equipment, and the employer has not deteremined if employees are exposed to chromium (VI) fumes above the permissible exposure limit for an 8 hour time weighted average.
Recent events (1)
  • — Z (O) $0

View Veterans Affairs: Puget Sound Health Care System's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335655031.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.