BATAVIA, IL —
OSHA Inspection: CFC WIREFORMS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CFC WIREFORMS, INC. in 1000 DOUGLAS ROAD, BATAVIA, IL 60510 (NAICS 332999). OSHA activity number 335662789.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CFC WIREFORMS, INC.
- Site address
- 1000 DOUGLAS ROAD
- City
- BATAVIA
- State
- IL
- ZIP
- 60510
- Mailing
- 1000 DOUGLAS ROAD, BATAVIA, IL 60510
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 37
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C06 I
- Issued
- Sep 27, 2012
- Abate by
- Oct 19, 2012
- Penalty
- Initial $2,100 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: The employer failed to perform periodic inspections to their energy control procedures. An evaluation was not conducted at least annually. Lockout tagout was performed when troubleshooting, servicing and maintaining equipment such as mechanical power presses and CNC machines. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (O) $0
- — Z (S) $2100
1910.178 L04 III
- Issued
- Sep 27, 2012
- Abate by
- Oct 19, 2012
- Penalty
- Initial $2,100 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operators performance was not conducted at least once every 3 years Employer failed to certify that each authorized forklift operator had been trained and evaluated every three years. Employees were operating powered industrial vehicles to load and unload materials received and to transport material to the different workstations. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $0
- — Z (S) $2100
1910.217 C01 I
- Issued
- Sep 27, 2012
- Abate by
- Oct 19, 2012
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es) Walsh Press M38 SN#1096: The employer failed to use guards that would prevent access to the point of operation. The press had been modified to fit production needs. The front and side guard had been removed from the press. Employees were manually activating the cycle by pressing a foot pedal located inches from the point of operation. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $2940
- — Z (S) $4900
1910.217 E01 I
- Issued
- Sep 27, 2012
- Abate by
- Nov 2, 2012
- Penalty
- Initial $4,900 · Current $0 Reduced
General-duty citation text
29 CFR 1910.217(e)(1)(i): A program of periodic and regular inspections of mechanical power press(es) was not established and followed to ensure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment: The employer failed to perform and document periodic inspections to their presses to ensure that their equipment and safeguarding was in safe operating condition. Maintenance certification records were not kept. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $0
- — Z (S) $4900
More inspections at CFC Wireforms, INC.