HARTSDALE, NY ·
OSHA Inspection: ASC REMODELING
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of ASC REMODELING in 156 CENTRAL AVENUE, HARTSDALE, NY 10530 (NAICS 238350). OSHA activity number 335672184.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ASC REMODELING
- Site address
- 156 CENTRAL AVENUE
- City
- HARTSDALE
- State
- NY
- ZIP
- 10530
- Mailing
- 2 TRAIL OF THE MAPLES, PUTNAM VALLEY, NY 10579
What kind of inspection was it?
- Inspection type
- Programmed Related (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 2
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1926.304 H01
- Issued
- Jan 28, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut: On or about 8/9/12 Location: 156 Central Avenue, Hartsdale, NY 10530 a) The Ridgid table saw did not have a guard covering the blade above the table.
Recent events (1)
- · Z (S) $2000
1926.403 B02
- Issued
- Jan 28, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: On or about 8/9/12 Location: 156 Central Avenue, Hartsdale, NY 10530 a) A metal quad outlet "J" box was used as a distribution point attached to the end of a temporary flexable cord. "J" boxes are only to used when attached to building framework with perminate wiring.
Recent events (1)
- · Z (S) $2000
1926.405 G02 IV
- Issued
- Jan 28, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: On or about 8/9/12 Location: 156 Central Avenue, Hartsdale, NY 10530 a) The flexable cord entering the metal "J" box did not have strain relief.
Recent events (1)
- · Z (S) $0
1926.404 B01 I
- Issued
- Jan 28, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: On or about 8/9/12 Location: 156 Central Avenue, Hartsdale, NY 10530 a) Employees using extension cords and a home made electrical distribution box were not protected by a ground fault circuit interrupter.
Recent events (1)
- · Z (S) $2000
More inspections in this industry (NAICS 238350)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335672184.