Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WILHEIT PACKAGING, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WILHEIT PACKAGING, LLC in 1527 MAY DRIVE, GAINESVILLE, GA 30507 (NAICS 322211). OSHA activity number 335673414.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wilheit Packaging, LLC — free Get an email when a new federal OSHA severe-injury report for Wilheit Packaging, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1527 MAY DRIVE
City
GAINESVILLE
State
GA
ZIP
30507
Mailing
1527 MAY DRIVE, GAINESVILLE, GA 30507
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322211
Employees
72
Ownership type
A

11 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 72 exposed
Issued
Sep 25, 2012
Abate by
Nov 7, 2012
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    On or about 8/8/12 at 1527 May Dirve Gainesville, GA; the employerdid not develop an energy control program where were required to perform maintenance and cleaning of the gluer, progressive slitter, the band saw, and the auto-box, exposing them to an amputation hazard.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $4900

1910.157 C01

Serious Gravity 5 1 instance 72 exposed
Issued
Sep 25, 2012
Penalty
Initial $2,023 · Current $1,011 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:    On or about 08/08/12 at 1527 May Drive Gainesville, GA; employees were exposed to smoke inhalation and burn hazards where a portable fire extinguisher was blocked by stored cardboard boxes.
Recent events (2)
  • — I (S) $1011
  • — Z (S) $2023

1910.157 E02

Serious Gravity 1 1 instance 72 exposed
Issued
Sep 25, 2012
Abate by
Nov 7, 2012
Penalty
Initial $1,785 · Current $892 Reduced
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:    On or about 8/8/12 at 1527 May Drive Gainesville, GA; employees were exposed to potential smoke inhalation and burn hazards where the 43 portable fire extinguishers that are on site were not inspected since October 2011.
Recent events (2)
  • — I (S) $892
  • — Z (S) $1785

1910.176 B

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 25, 2012
Penalty
Initial $2,975 · Current $1,485 Reduced
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse:    On or about 8/8/12 at 1527 May Street Gainesville, GA; employees were exposed to crush hazards where stacked pallets of folded cardboard boxes were observed toppled over in the aisle B area.
Recent events (2)
  • — I (S) $1485
  • — Z (S) $2975

1910.215 B09

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 25, 2012
Penalty
Initial $2,023 · Current $1,011 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    On or about 8/8/12 at 1527 May Drive Gainesville, GA; employees were exposed to potential injuries where the opening of the tongue guard was greater than half an inch.
Recent events (2)
  • — I (S) $1011
  • — Z (S) $2023

1910.242 B

Serious Gravity 5 2 instances 72 exposed
Issued
Sep 25, 2012
Abate by
Oct 2, 2012
Penalty
Initial $3,570 · Current $1,785 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    On or about 8/8/12 at 1527 May Drive Gainesville, GA; employees were exposed to struck-by hazards where air nozzles were adjusted above the 30 PSI limit:         A. Mechanics shop - where compressed air was being used to clean the floors, the air nozzle released compressed air at > 100 PSI.         B. GW3 shop- where compressed air was being used to clean dust off the machine, the air nozzle released compressed air at 78 PSI.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $3570

1910.303 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 25, 2012
Abate by
Oct 2, 2012
Penalty
Initial $1,785 · Current $904 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    On or about 8/8/12 at 1527 May Drive Gainesville, GA; employees are exposed to electrical hazards where a 110 V flexible cord is used to power a metallic duplex electrical outlet that was powering a computer, printer, 2 way charger, and a thermal label printer.
Recent events (2)
  • — I (S) $904
  • — Z (S) $1785

1910.305 G01 IV A

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 25, 2012
Abate by
Oct 2, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    On or about 8/8/12 at 1527 May Drive Gainesville, GA; employees were exposed to electrical hazards where a 110 V electrical extension cord was plugged into a 110 V wall outlet for use as permanent wiring.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B07 I

Serious Gravity 5 2 instances 2 exposed
Issued
Sep 25, 2012
Abate by
Oct 2, 2012
Penalty
Initial $3,570 · Current $1,785 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment    On or about 8/8/12 at 1527 May Drive Gainesville, GA; employees were exposed to electrical hazards where:    A) Progressive Slitter Machine - the 480 V, Square D electrical control box has an unused opening.   B)  RJE Machinery Inc. Band Saw - the 480 V, electrical control box has an unused opening.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $3570

1910.303 G01 I A

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 25, 2012
Penalty
Initial $3,570 · Current $1,785 Reduced
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening whwere they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:    On or about 8/8/12 at 1527 May Drive Gainesville, GA; employees were exposed to electrical hazards where the 480 V electrical box that controlled the:    1. 220 V gluer  2. 480 V slitter  3. 480 V bandsaw  4. 480 V auto box    was unable to be opened due to being blocked by a pallet containing chemicals for the foam machine. (Part B)
Recent events (2)
  • — I (S) $1785
  • — Z (S) $3570

1910.305 G02 III

Serious Gravity 1 2 instances 2 exposed
Issued
Sep 25, 2012
Abate by
Oct 2, 2012
Penalty
Initial $1,785 · Current $892 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    On or about 8/8/12 at 1527 May Drive Gainesville, GA; employees were exposed to electrical hazards where 480 V cords did not have adequate strain relief devices on the:    A) Progressive Slitter machine.  B) RJE Machinery, Inc. Bandsaw.
Recent events (2)
  • — I (S) $892
  • — Z (S) $1785

View Wilheit Packaging, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335673414.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.