CINCINNATI, OH —
OSHA Inspection: AMPAC PLASTICS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of AMPAC PLASTICS, INC. in 12025 TRICON RD., CINCINNATI, OH 45246 (NAICS 326111). OSHA activity number 335682803.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMPAC PLASTICS, INC.
- Site address
- 12025 TRICON RD.
- City
- CINCINNATI
- State
- OH
- ZIP
- 45246
- Mailing
- 12025 TRICON RD., CINCINNATI, OH 45246
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326111
- Employees
- 240
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 II
- Issued
- Aug 14, 2012
- Abate by
- Sep 13, 2012
- Penalty
- Initial $3,600 · Current $2,520 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items of this section: (a) The energy control (lockout) procedures for the Extruder #10, did not clearly state the different ways to isolate the machine and different sections that might be worked on, and where the main lockable disconnect switch is located for isolating the entire electrical power to the machine.
Recent events (2)
- — I (S) $2520
- — Z (S) $3600
1910.147 D04 II
- Issued
- Aug 14, 2012
- Abate by
- Aug 15, 2012
- Penalty
- Initial $3,600 · Current $2,520 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(ii): Lockout devices utilized were not affixed in a manner that held the energy isolating device in a safe or off position: (a) The lockout hasp and lockout lock for a maintenance employee working on the #10 Extruder did not hold the main power disconnect switch in the safe or off position in that the tab on the disconnect switch handle that the hasp went through was broken off and would not hold the disconnect in the safe or off position.