Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMPAC PLASTICS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AMPAC PLASTICS, INC. in 12025 TRICON RD., CINCINNATI, OH 45246 (NAICS 326111). OSHA activity number 335682803.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ampac Plastics, INC. — free Get an email when a new federal OSHA severe-injury report for Ampac Plastics, INC. is published. One employer, no account, unsubscribe in one click.
Site address
12025 TRICON RD.
City
CINCINNATI
State
OH
ZIP
45246
Mailing
12025 TRICON RD., CINCINNATI, OH 45246
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326111
Employees
240
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 14, 2012
Abate by
Sep 13, 2012
Penalty
Initial $3,600 · Current $2,520 Reduced
29 CFR 1910.147(c)(4)(ii):   The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items of this section:  (a) The energy control (lockout) procedures for the Extruder #10, did not clearly state the different ways to isolate the machine and different sections that might be worked on, and where the main lockable disconnect switch is located for isolating the entire electrical power to the machine.
Recent events (2)
  • — I (S) $2520
  • — Z (S) $3600

1910.147 D04 II

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 14, 2012
Abate by
Aug 15, 2012
Penalty
Initial $3,600 · Current $2,520 Reduced
29 CFR 1910.147(d)(4)(ii):   Lockout devices utilized were not affixed in a manner that held the energy isolating device in a safe or off position:  (a) The lockout hasp and lockout lock for a maintenance employee working on the #10 Extruder did not hold the main power disconnect switch in the safe or off position in that the tab on the disconnect switch handle that the hasp went through was broken off and would not hold the disconnect in the safe or off position.
Recent events (2)
  • — I (S) $2520
  • — Z (S) $3600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335682803.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.