Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: NORTH AMERICAN SAFETY VALVE INDUSTRIES, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of NORTH AMERICAN SAFETY VALVE INDUSTRIES, INC. in 1500 IRON STREET, NORTH KANSAS CITY, MO 64116 (NAICS 332919). OSHA activity number 335691184.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch North American Safety Valve Industries, INC. for free Get an email when a new federal OSHA severe-injury report for North American Safety Valve Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1500 IRON STREET
City
NORTH KANSAS CITY
State
MO
ZIP
64116
Mailing
1500 IRON STREET, NORTH KANSAS CITY, MO 64116
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332919
Employees
37
Ownership type
Private (A)

3 citations on file for this inspection.

1910.132 D01

Serious Gravity 1 1 instance 5 exposed
Issued
Aug 20, 2012
Abate by
Sep 19, 2012
Penalty
Initial $2,100 · Current $1,470 Reduced
29 CFR 1910.132(d)(1)     The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):    (a) On, or at dates prior to, August 1st, 2012 the employer did not accomplish a workplace hazard assessment to identify personal protective equipment needs for employees performing work tasks.
Recent events (2)
  • · I (S) $1470
  • · Z (S) $2100

1910.303 C03 I

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Aug 20, 2012
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.303(c)(3)(i):     All splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose:    (a) On or before August 1st, 2012, employees of North American Safety Valve Industries were exposed to contact with electrical current hazards when a splice in the electrical cord of a horizontal band saw was not covered with proper insulation.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2800

1910.303 G01

Deleted Serious Gravity 5 2 instances 3 exposed
Issued
Aug 20, 2012
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.303(g)(1)      Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.    (a) On, or before, August 1st, 2012, employees of North American Safety Valve Industries were exposed to hazard in multiple locations on the workroom floor from failure to provide and maintain adequate working space in front of various electrical panels.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2800

View North American Safety Valve Industries, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335691184.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.