Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: POWER & COMPOSITE TECHNOLOGIES, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of POWER & COMPOSITE TECHNOLOGIES, LLC in 200 WALLINS CORNERS RD., AMSTERDAM, NY 12010 (NAICS 326199). OSHA activity number 335691788.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Power & Composite Technologies, LLC for free Get an email when a new federal OSHA severe-injury report for Power & Composite Technologies, LLC is published. One employer, no account, unsubscribe in one click.
Site address
200 WALLINS CORNERS RD.
City
AMSTERDAM
State
NY
ZIP
12010
Mailing
200 WALLINS CORNERS RD., AMSTERDAM, NY 12010
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
96
Ownership type
A

18 citations on file for this inspection.

1910.38 E

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Feb 7, 2013
Abate by
Feb 14, 2013
Penalty
Initial $2,975 · Current $0 Reduced
29 CFR 1910.38(e): The employer failed to designate and train employees to assist in a safe and orderly evacuation of other employees.  a) Throughout facility- On or about 08/09/12- The employer did not ensure that managers, supervisors,  and team leaders were trained in established procedures for safe and orderly evacuation.
Recent events (3)
  • · F (S) $0
  • · C (S) $2975
  • · Z (S) $2975

1910.106 E02 II

Serious Gravity 5 4 instances 1 exposed
Issued
Feb 7, 2013
Abate by
Feb 14, 2013
Penalty
Initial $2,975 · Current $1,750 Reduced
29 CFR 1910.106(e)(2)(ii): Flammable or combustible liquids were not stored in tanks or closed containers.    a) Hand layup area- On or about 08/09/12- 55 gallon drum containing 73517 insulating varnish was not equipped with a bung cover.    b) Hand layup area- On or about 08/09/12- 55 gallon drum containing recycled acetone was not equipped with a bung cover.    c) Flammable storage area- On or about 08/09/12- 55 gallon drum containing recycled acetone was not equipped with a bung cover.
Recent events (3)
  • · F (S) $1750
  • · C (S) $2975
  • · Z (S) $2975

1910.106 E02 IV B

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 7, 2013
Abate by
Feb 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(2)(iv)(b): Where flammable or combustible liquids are used or handled, except in closed containers, means were not provided to dispose promptly and safely of leakage or spills.    a) Hand layup area- on or about 08/09/12- Employees open pouring combustible and flammable liquids into quart containers spilled Acetone, DDM-9, and 73517 insulating varnish.
Recent events (3)
  • · F (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.106 E06 I

Serious Gravity 5 2 instances 1 exposed
Issued
Feb 7, 2013
Abate by
Feb 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.    (a) Hand layup area- on or about 08/09/12- 18v battery operated hand drill was used for mixing flammable liquids and combustible resins.
Recent events (3)
  • · F (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.106 E07 I C

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 7, 2013
Abate by
Feb 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(7)(i)(c):  Locations where flammable vapor-air mixtures may exist under abnormal conditions and for a distance beyond Division 1 locations were not classified Division 2 according to the requirements of subpart S of this part. These locations include an area within 20 feet horizontally, 3 feet vertically beyond a Division 1 area, and up to 3 feet above floor or grade level within 25 feet, if indoors, or 10 feet if outdoors, from any pump, bleeder, withdrawal fitting, meter, or similar device handling Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 F (37.8 C). Pits provided with adequate mechanical ventilation within a Division 1 or 2 area shall be classified Division 2. If only Category 3 flammable liquids with a flashpoint at or above 100 F (37.8 C) or Category 4 flammable liquids are handled, then ordinary electrical equipment is satisfactory though care shall be used in locating electrical apparatus to prevent hot metal from falling into open equipment.    a) Flammable storage area- On or about 08/09/12 - Storage area containing approximately 150 gallons of Cat 2 and 3 flammable liquids stored in portable (55gal.) fifty five gallon drums including but not limited to:  acetone, recycled acetone, and xylene was not equipped with Class 1 Division 2 electrical components.    b) Hand lay-up booth- On or about 8/9/12- 110v-120v electrical fixture was not equipped with a cover.
Recent events (3)
  • · F (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.179 L03 I

Other-than-serious 10 instances 7 exposed
Issued
Feb 7, 2013
Abate by
Feb 14, 2013
Penalty
Initial $2,380 · Current $0 Reduced
29 CFR 1910.179(l)(3)(i): Unsafe condition(s) disclosed during the frequent or periodic inspection(s) required by 29 CFR 1910.179(j) were not corrected before operation of the crane(s) was resumed:    a) Area #2- On and before 8/09/12- Coffing 500lb. electrical hoist sn#161-sw identified in inspection report dated 04/11/12 with 6 random broken wires and attached to a 1 ton trolley on a 500 lb monorail was not repaired.    b) Monrail #2- On and before 8/09/12- 2-Larin 1 ton chain falls mounted on 1/2 ton trolleys identified in an inspection report dated 04/11/12 had not been replaced or derated.    c) Stock rack- On and before 08/09/12- 1/2 ton chain block sn#060006 attached to a 1 ton trolley on a bridge rated for 1/2 ton identified in an inspection report dated 04/11/12 with worn ratchet, pawl and disc was not replaced and derated.    d) Slot armor area#3- On and before 08/09/12- Coffing 1/2 ton electric chain hoist #19 sn#JM3292RW stops do not prevent the unit from hitting a wall was also identified in inspection report dated 04/11/12 as attached to a trolley with no load rating.    e) Slot armor area#3- On and before 08/09/12- Coffing 1/2 ton electric chain hoist #20 sn#JLA-471-XN identified in inspection report dated 04/11/12 , stops were not adjusted to prevent the unit from hitting a wall is attached to a trolley with a 2 ton rating attached to a 1/2 ton rated monorail had not been repaired or derated.    f) Area #5 vacuum forming- On and before 08/09/12- Electric hoist 1, model PA400B no sn#, no mfg. identification, identified in inspection report dated 04/11/12 rated for 1/2 ton attached to a 500lb. monorail was not derated.    g) Area #5 vacuum forming- On and before 08/09/12- Harrington hoist sn#279242 identified in inspection report dated 04/11/12 rated for 1/2 ton on a 1 ton trolley attached to a 500lb. monorail was not derated.    h) Area #5 vacuum forming- On and before 08/09/12- ARO electric chain hoist sn#4690G79 identified in inspection report dated 04/11/12 as having 2 twisted chain links had not been repaired.    i) Area #12 lathes- On and before 08/09/12- Larin 1 ton hoist identified in inspection report dated 04/11/12 as attached to a 1/2 ton jib was not derated.
Recent events (3)
  • · F (O) $0
  • · C (S) $2380
  • · Z (S) $2380

1910.212 A03 II

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Feb 7, 2013
Abate by
Feb 14, 2013
Penalty
Initial $2,975 · Current $0 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    a) Slot armor area- On and before 08/08/12- 10" Delta radial arm saw used to cut composite materials was not equipped with a blade guard.
Recent events (3)
  • · F (S) $0
  • · C (S) $2975
  • · Z (S) $2975

1910.305 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 7, 2013
Abate by
Feb 14, 2013
Penalty
Initial $1,785 · Current $1,000 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    a) Slot armor area- On or about 08/10/12- Strain relief was not provided for the flexible cord supplying 110-120v electrical power to a pedestal fan.
Recent events (3)
  • · F (S) $1000
  • · C (S) $1785
  • · Z (S) $1785

5(a)(1)

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 7, 2013
Abate by
Feb 14, 2013
Penalty
Initial $2,975 · Current $2,000 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by falling loads.    a) Stock rack- On or about 8/10/2012- Below-the hook lifting device used to lift composite resin sheets had no rated load capacity or manufacturer's specifcations.     b) Area #11 connectors- On and before 08/09/12- Harrington 1/2 ton chainfall sn#103752 identified in inspection report dated 04/11/12 attached to an unrated lug in in the ceiling; lug was not rated for its capacity.
Recent events (3)
  • · F (S) $2000
  • · C (S) $2975
  • · Z (S) $2975

1910.134 C02 II

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 7, 2013
Abate by
Feb 14, 2013
Penalty
Initial $4,200 · Current $2,700 Reduced
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:    a) Hand lay-up area- On or about 08/09/12- Employee was provided an elastomeric half face MSA respirator with GME multi-gas cartridges without being medically evaluated and trained in the use of the respirator.    Power & Composite Technologies, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.134(c)(2)(ii) which was contained in OSHA inspection 311977474, citation 1 item 1 and was affirmed as a final order on 05/05/2009, with respect to a workplace located at 200 Wallins Corners Rd. Amsterdam, NY 12010.
Recent events (3)
  • · F (S) $2700
  • · C (R) $4200
  • · Z (R) $4200

1910.147 C06 I

Other-than-serious 1 instance 2 exposed
Issued
Feb 7, 2013
Abate by
Feb 14, 2013
Penalty
Initial $5,600 · Current $700 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    a) Throughout facility- On or about 08/09/12-  The employer had not conducted an annual inspection of lockout/tagout procedures for equipment with multiple energy sources, including but not limited to: large batch ovens, small batch ovens, VT-1, New Centurt machine etc. since 05/07/2009.    Power & Composite Technologies, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(6)(i) which was contained in OSHA inspection 311977474, citation 1 item 2(b) and was affirmed as a final order on 05/05/2009, with respect to a workplace located at 200 Wallins Corners Rd. Amsterdam, NY 12010.
Recent events (3)
  • · F (O) $700
  • · C (R) $5600
  • · Z (R) $5600

1910.151 C

Deleted Repeat Gravity 5 1 instance 1 exposed
Issued
Feb 7, 2013
Abate by
Feb 14, 2013
Penalty
Initial $5,600 · Current $0 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    a) Hand lay-up area- On or about 08/09/12- Eyewash station was not provided for employees using and dispensing corrosive Luperox DDM-9.    Power & Composite Technologies, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.151(c) which was contained in OSHA inspection 311977474, citation 1 item 3 and was affirmed as a final order on 05/05/2009, with respect to a workplace located at 200 Wallins Corners Rd. Amsterdam, NY 12010.
Recent events (3)
  • · F (R) $0
  • · C (R) $5600
  • · Z (R) $5600

1910.134 C02 I

Deleted Repeat 1 instance 1 exposed
Issued
Feb 7, 2013
Abate by
Feb 14, 2013
Penalty
Initial $140 · Current $0 Reduced
29 CFR 1910.134(c)(2)(i):  An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in Appendix D to this section ("Information for Employees Using Respirators When Not Required Under the Standard"); and  a) Hand lay-up area- On or about 08/09/12- Employee was provided an elastomeric half face MSA respirator with GME multi-gas cartridges without being provided appendix D of the respirator standard.  Power & Composite Technologies, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.134(c)(2)(i) which was contained in OSHA inspection 311977474, citation 1 item 1 and was affirmed as a final order on 05/05/2009, with respect to a workplace located at 200 Wallins Corners Rd. Amsterdam, NY 12010.
Recent events (3)
  • · F (R) $0
  • · C (R) $140
  • · Z (R) $140

1910.178 L04 III

Repeat 1 instance 3 exposed
Issued
Feb 7, 2013
Abate by
Feb 14, 2013
Penalty
Initial $140 · Current $140
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operators performance was not conducted at least once every 3 years    a) Throughout facility- On or about 08/09/12- The employer faild to evaluate the performance of fork truck operators at least every three years.    Power & Composite Technologies, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.178(l)(4)(iii) which was contained in OSHA inspection 311977474, citation 2 item 1 and was affirmed as a final order on 05/05/2009, with respect to a workplace located at 200 Wallins Corners Rd. Amsterdam, NY 12010.
Recent events (3)
  • · F (R) $140
  • · C (R) $140
  • · Z (R) $140

1910.124 J03

Deleted Other-than-serious 1 instance 2 exposed
Issued
Feb 7, 2013
Abate by
Feb 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.124(j)(3): Periodic inspections of all dipping and coating equipment, including covers, drains, overflow piping, and electrical and fire-extinguishing systems were not conducted, and deficiencies were not promptly corrected:    a) Filament winding area- On and before 08/27/12- Justrite flammable liquid safety rinse tank foot depression mechanism for the drop down cover was bent.
Recent events (3)
  • · F (O) $0
  • · C (O) $0
  • · Z (O) $0

1910.138 B

Deleted Other-than-serious 3 instances 2 exposed
Issued
Feb 7, 2013
Abate by
Feb 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.138(b): The employer did not base selection of appropriate hand protection on an evaluation of the performance characteristics of the hand protection relative to the tasks to be performed, conditions present, duration of use, and the hazards and potential hazards identified:    a) Reroll area- On or about 08/09/12- Employee was exposed to skin contact with acetone in the event of glove break through when using latex gloves while washing and handling parts.    b) Hand Layup area- On or about 08/09/12- Employee was exposed to skin contact with methyl ethyl ketone and styrene in the event of glove break through when using natural rubber and neoprene blend gloves for hand layup of composite materials.    c) Hand Layup area- On or about 08/09/12- Employee was exposed to skin contact with acetone in the event of chemical glove break through when using latex gloves while washing and handling parts.
Recent events (3)
  • · F (O) $0
  • · C (O) $0
  • · Z (O) $0

1910.157 C01

Other-than-serious 5 instances 5 exposed
Issued
Feb 7, 2013
Abate by
Feb 14, 2013
Penalty
Initial $595 · Current $0 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: (a)(LOCATION)(IDENTIFY SPECIFIC OPERATION(S) AND CONDITION(S))(DESCRIBE HAZARD(S))    a) Slot armor area- On or about 08/09/12- Buckeye brand ABC fire extinguisher was not equipped with location labeling.    b) Hand Lay-up area- On or about 08/09/12- Buckeye brand ABC fire extinguisher was not equipped with location labeling.    c) Filament area- On or about 08/09/12- Buckeye brand ABC fire extinguisher was not equipped with location labeling.    d) Flammable area behind desk- On or about 08/09/12- Buckeye brand ABC fire extinguisher was not equipped with location labeling.    e) Loadijng dock area near door- On or about 08/09/12- Buckeye brand ABC fire extinguisher was not equipped with location labeling.            NOTE: APPLIES WHEREVER EXTINGUISHERS ARE PROVIDED FOR EMPLOYEE USE INCLUDING EXTINGUISHERS ON THE OUTSIDE OF WORKPLACE BUILDINGS OR STRUCTURES
Recent events (3)
  • · F (O) $0
  • · C (O) $595
  • · Z (O) $595

1910.1200 F01 II

Other-than-serious 1 instance 1 exposed
Issued
Feb 7, 2013
Abate by
Feb 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(ii):  The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings:    a) Hand Lay-up area- on and before 08/09/12- Dispensing container containing DDM-9 an organic peroxide was not equipped with a hazard warning labeling.
Recent events (3)
  • · F (O) $0
  • · C (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335691788.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.