LAKEVIEW, OR ·
OSHA Inspection: BUREAU OF LAND MANAGEMENT, LAKEVIEW FIRE COMPOUND
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BUREAU OF LAND MANAGEMENT, LAKEVIEW FIRE COMPOUND in 1000 SOUTH 9TH STREET, LAKEVIEW, OR 97630 (NAICS 922160). OSHA activity number 335698619.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BUREAU OF LAND MANAGEMENT, LAKEVIEW FIRE COMPOUND
- Site address
- 1000 SOUTH 9TH STREET
- City
- LAKEVIEW
- State
- OR
- ZIP
- 97630
- Mailing
- 1301 SOUTH G STREET, LAKEVIEW, OR 97630
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 922160
- Employees
- 48
- Ownership type
- Federal government (D)
Citations
5 citations on file for this inspection.
1910.23 E09
- Issued
- Sep 20, 2012
- Abate by
- Oct 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(e)(9): Wall opening barriers (rails, rollers, picket fences, and half doors) shall be of such construction and mounting that, when in place at the opening, the barrier is capable of withstanding a load of at least 200 pounds applied in any direction (except upward) at any point on the top rail or corresponding member: Employees were potentially exposed to serious injury from a fall to a lower level. The hazard was located in the Fire Cache building where the gate in the storage area was not secured by a positive means.
Recent events (1)
- · Z (S) $0
1910.132 D01
- Issued
- Sep 20, 2012
- Abate by
- Oct 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): (a) Employees were potentially exposed to serious injury from a fall to a lower level. The hazard was located in the Fire Cache, where the employer had not assessed whether fall protection was needed when employees were working next to a loading platform when the gate was opened.
Recent events (1)
- · Z (S) $0
1910.212 A03 II
- Issued
- Sep 20, 2012
- Abate by
- Oct 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposed an employee to injury, was not guarded: (a) Fleet maintenance shop: On or about August 7, 2012 and times prior thereto, the 50 ton hydraulic press was not guarded by a physical guard or by distance. This exposed employees to serious injury if the work piece were to break and strike the employee. (b) Fleet maintenance shop: On or about August 7, 2012 and times prior thereto, a drill press was not guarded at the point of operation. This exposed employees to laceration hazard to the hands.
Recent events (1)
- · Z (S) $0
1910.305 B01 II
- Issued
- Sep 20, 2012
- Abate by
- Oct 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed: (a) Employees were potentially exposed to serious injury from a heater timer switch fitting with exposed electrical parts that was not effectively closed. The fitting was located by the north exit door of the Interagency Dispatch Center, at the Lakeview Fire Compound, address of 1000 S 9th Street in Lakeview, Oregon.
Recent events (1)
- · Z (S) $0
1910.178 A04
- Issued
- Sep 20, 2012
- Abate by
- Oct 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affected capacity and safe operation were performed by the customer or user without manufacturers written approval, and the capacity, operation and maintenance instruction plates, tags or decals were not changed accordingly: (a) The inspection revealed that modifications had been made to one of the forks on the Wiggins model #WG106ATS powered industrial truck, also known as "Mr. Wiggins", without the manufacturers written approval. Mr. Wiggins was located in front of the fire cache building at the Lakeview Fire Compound, address 1000 S 9th Street in Lakeview, Oregon.
Recent events (1)
- · Z (O) $0
More inspections in this industry (NAICS 922160)
More inspections in OR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335698619.