OSHA Inspection: GENESIS METAL BUILDING ERECTORS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GENESIS METAL BUILDING ERECTORS, INC. in 200 GEORGIA, DEER PARK, TX 77536 (NAICS 238120). OSHA activity number 335715033.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Genesis Metal Building Erectors, INC. for free Get an email when a new federal OSHA severe-injury report for Genesis Metal Building Erectors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
200 GEORGIA
City
DEER PARK
State
TX
ZIP
77536
Mailing
20814 GOLDEN SKY LANE, RICHMOND, TX 77469
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
9
Ownership type
Private (A)

3 citations on file for this inspection.

1926.602 C01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 18, 2012
Abate by
Oct 19, 2012
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.602(c)(1)(ii): Modifications or additions affecting the safe operation of the equipment were  made without the manufacturer's written approval:    On August 14, 2012, at 200 Georgia, Deer Park, TX, employees were exposed to struck-by hazards when using a forklift with a 2740 pound load suspended underneath the load bearing tines while using only one tine, the method of "free rigging."
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1926.758 F02

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 18, 2012
Abate by
Oct 19, 2012
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.758(f)(2): Both ends of all steel joists or cold-formed joists were not fully bolted and/or welded to the support structure before allowing an employee on the joists:    on August 14, 2012, at 200 Georgia, Deer Park, TX, employees were exposed to fall hazards at a height of approximately 16 feet when erecting a system engineered building.  The joist an employee was using as a working surface was fastened on one end to the column and the other end was supported by a forklift using the method of "free rigging."
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1910.178 L01 II

Other-than-serious 1 instance 3 exposed
Issued
Oct 18, 2012
Abate by
Nov 17, 2012
Penalty
Initial $400 · Current $240 Reduced
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck:    a) at 200 Georgia Street, Deer Park, TX, employees were exposed to struck-by hazards due to the lack of training of the forklift operator on a Skytrack Model 8042, serial number PZ939H3239.