Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: NATIONAL PARK SERVICE NORTH CASCADES, NEWHALEM WAREHOUSE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NATIONAL PARK SERVICE NORTH CASCADES, NEWHALEM WAREHOUSE in STATE ROUTE 20, NEWHALEM, WA 98283 (NAICS 493110). OSHA activity number 335736013.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch National Park Service North Cascades, Newhalem Warehouse for free Get an email when a new federal OSHA severe-injury report for National Park Service North Cascades, Newhalem Warehouse is published. One employer, no account, unsubscribe in one click.
Site address
STATE ROUTE 20
City
NEWHALEM
State
WA
ZIP
98283
Mailing
810 STATE ROUTE 20, SEDRO WOOLLEY, WA 98284
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
5
Ownership type
Federal government (D)

10 citations on file for this inspection.

1910.23 E01

Other-than-serious 1 instance 5 exposed
Issued
Aug 30, 2012
Abate by
Oct 15, 2012
Penalty
Initial $0 · Current $0
29CFR 1910.23(e)(1): Standard railing did not consist of top rail, intermediate rail, and posts:     a) South Side Exterior stairway, where the railing on the stairway was not equipped with midrails.
Recent events (1)
  • · Z (O) $0

1910.36 G02

Other-than-serious 1 instance 5 exposed
Issued
Aug 30, 2012
Abate by
Oct 15, 2012
Penalty
Initial $0 · Current $0
29CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points:    a) West side of the warehouse, where aisle ways ranged from 16-19 inches in width due to placement of stored items.
Recent events (1)
  • · Z (O) $0

1910.37 B02

Other-than-serious 1 instance 5 exposed
Issued
Aug 30, 2012
Abate by
Oct 15, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2):  Each exit was not clearly visible and marked by a sign reading "Exit":    a) Warehouse, where the designated emergency exit doors were not equipped with exit signs.
Recent events (1)
  • · Z (O) $0

1910.37 B05

Other-than-serious 2 instances 5 exposed
Issued
Aug 30, 2012
Abate by
Oct 15, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet):    a) Eastside of the Warehouse, where  two personnel doors located on the south end of the room were not equipped with signage.
Recent events (1)
  • · Z (O) $0

1910.157 C01

Other-than-serious 1 instance 5 exposed
Issued
Aug 30, 2012
Abate by
Oct 15, 2012
Penalty
Initial $0 · Current $0
29CFR1910.157(c)(1): Fire extinguishers were not mounted,  located and  identified so that they were readily accessible to employees without subjecting the employees to possible injury:    a) Warehouse, where employees would be expected to fight incipient stage fires, the fire extinguisher adjacent to the west side personnel door was not mounted.
Recent events (1)
  • · Z (O) $0

1910.157 E02

Other-than-serious 1 instance 5 exposed
Issued
Aug 30, 2012
Abate by
Oct 15, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:     a) Warehouse, where employees would be expected to fight incipient stage fires, fire extinguishers were not inspected on a monthly basis.
Recent events (1)
  • · Z (O) $0

1910.157 G02

Other-than-serious 1 instance 5 exposed
Issued
Aug 30, 2012
Abate by
Oct 15, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting was not provided to all employees upon initial employment, and at least annually thereafter:       a) Warehouse, where employees would be expected to fight incipient stage fires, training was not provided.
Recent events (1)
  • · Z (O) $0

1910.176 C

Other-than-serious 1 instance 5 exposed
Issued
Aug 30, 2012
Abate by
Oct 15, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.176(c): Storage areas were not kept free from accumulation of materials that constituted hazards from tripping, fire, explosion or pest harborage:    a) South End Storage Room, where items strewn on the floor included televisions, computers, and bags filled with appliances.
Recent events (1)
  • · Z (O) $0

1910.303 G01 II

Other-than-serious 1 instance 5 exposed
Issued
Aug 30, 2012
Abate by
Oct 15, 2012
Penalty
Initial $0 · Current $0
1910.303(g)(1)(ii): Working space for equipment likely to require examination, adjustment, servicing, or maintenance while energized was used for storage:     a) West side of the warehouse, where items including boxes containing paper goods were stored in front of the circuit panels.
Recent events (1)
  • · Z (O) $0

1910.305 J01 I

Other-than-serious 1 instance 5 exposed
Issued
Aug 30, 2012
Abate by
Oct 15, 2012
Penalty
Initial $0 · Current $0
29CFR1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles may have no live parts normally exposed to employee contact. However, rosettes and cleat-type lampholders and receptacles located at least 2.44 m (8.0 ft) above the floor may have exposed terminals:    a) Warehouse, where boxes containing paper goods were stored next to light fixtures equipped with unguarded single bulbs.
Recent events (1)
  • · Z (O) $0

View National Park Service North Cascades, Newhalem Warehouse's full OSHA safety record →