Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: L.F. MANUFACTURING, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of L.F. MANUFACTURING, INC. in 119 SOUTH WASHINGTON AVE., LAUREL, MT 59044 (NAICS 326199). OSHA activity number 335739405.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch L.F. Manufacturing, INC. — free Get an email when a new federal OSHA severe-injury report for L.F. Manufacturing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
119 SOUTH WASHINGTON AVE.
City
LAUREL
State
MT
ZIP
59044
Mailing
PO BOX 206, LAUREL, MT 59044
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
81
Ownership type
A

14 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 6 instances 20 exposed
Issued
Dec 17, 2012
Abate by
May 20, 2013
Penalty
Initial $6,300 · Current $7,000
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire and explosion hazards:    (c) Outside Storage Area: On or about August 14, 2012, and at times prior thereto, employees were exposed to fire and explosion hazards due to the storage of organic peroxide catalyst (oxidizer) within an incompatible and combustible fiberglass hut fabricated without fire retardant.     (e) Outside Storage Area: On or about August 14, 2012, and at times prior thereto, employees were exposed to fire and explosion hazards due to the storage of organic peroxide catalyst (oxidizer) approximately 12 feet from incompatible flammable resin.
Recent events (3)
  • — F (S) $7000
  • — C (S) $6300
  • — Z (S) $6300

1910.107 C03

Deleted Serious Gravity 10 2 instances 20 exposed
Issued
Dec 17, 2012
Abate by
Jan 14, 2013
Penalty
Initial $6,300 · Current $0 Reduced
29 CFR 1910.107(c)(3): Space-heating appliances, steampipes, or hot surfaces were located in a spraying area where deposits of combustible residues may readily accumulate.    (a) Stock Tank Area: On or about August 14, 2012, and at times prior thereto, employees were exposed to fire and explosion hazards while applying flammable and combustible liquids such as, but not limited to, resin solution, gelcoat, and organic peroxide catalyst (oxidizer) in spraying areas that contained overhead radiant gas heaters with exposed piping and hot surfaces. The radiant gas heaters were located approximately 10 feet, up to approximately 11 feet, from the spraying surfaces and many contained deposits of accumulated splatter and residues on both the piping and surrounding areas.     (b) Tank Production Area: On or about August 14, 2012, and at times prior thereto, employees were exposed to fire and explosion hazards while applying flammable and combustible liquids such as, but not limited to, resin solution, gelcoat, and organic peroxide catalyst (oxidizer) in spraying areas that contained overhead radiant gas heaters with exposed piping and hot surfaces. The radiant gas heaters were located approximately 12 feet, up to approximately 15 feet, from the spraying surfaces and many contained deposits of accumulated splatter and residues on both the piping and surrounding areas.
Recent events (3)
  • — F (S) $0
  • — C (S) $6300
  • — Z (S) $6300

1910.107 C06

Serious Gravity 10 4 instances 20 exposed
Issued
Dec 17, 2012
Abate by
May 20, 2013
Penalty
Initial $6,300 · Current $7,000
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations:    (a) East Wall Stock Tank Area: On or about August 14, 2012, and at times prior thereto, employees were exposed to fire and explosion hazards while applying flammable gelcoat and organic peroxide catalyst (oxidizer) in a spray area that contained electrical equipment such as, but not limited to, an ACE relocateable power tap supplying power to the TFM digital fiberglass scale.     (b) North Wall Stock Tank Area: On or about August 14, 2012, and at times prior thereto, employees were exposed to fire and explosion hazards while applying flammable resin solution and organic peroxide catalyst (oxidizer) in a spray area that contained electrical equipment such as, but not limited to, a relocateable power tap supplying power to the TFM digital fiberglass scale and a radio.      (c) North Wall Stock Tank Area: On or about August 14, 2012, and at times prior thereto, employees were exposed to fire and explosion hazards while applying flammable resin solution and organic peroxide catalyst (oxidizer) in a spray area that contained electrical equipment such as, but not limited to, a multi-plug power cord supplying power from a relocateable power tap to the TFM digital fiberglass scale and a radio.     (d) West Wall Tank Production Area: On or about August 16, 2012, and at times prior thereto, employees were exposed to fire and explosion hazards while applying flammable resin solution and organic peroxide catalyst (oxidizer) in a spray area that contained electrical equipment such as, but not limited to, flexible power cords supplying permanent power to 120V industrial fans used to mitigate vapor accumulation from the spraying process.
Recent events (3)
  • — F (S) $7000
  • — C (S) $6300
  • — Z (S) $6300

1910.305 G01 IV A

Serious Gravity 10 1 instance 9 exposed
Issued
Dec 17, 2012
Abate by
Jan 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    (a) East / South Wall Tank Production Area: On or about August 16, 2012, and at times prior thereto, employees were exposed to fire hazards while using flexible power cords as permanent power for items such as, but not limited to, relocateable power taps in order to charge power tool batteries. The cords were strewn amongst 5 gallon, up to 55 gallon containers of flammable liquids such as acetone and resin solution.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.107 C07

Serious Gravity 10 1 instance 9 exposed
Issued
Dec 17, 2012
Abate by
May 20, 2013
Penalty
Initial $6,300 · Current $7,000
29 CFR 1910.107(c)(7): Electric lamps outside of but within 20 feet of spraying area(s), and not separated therefrom by partition(s), were not totally enclosed to prevent the falling of hot particles:    (a)Tank Production Area: On or about August 14, 2012, and at times prior thereto, employees were exposed to fire and explosion hazards while applying flammable and combustible liquids such as, but not limited to, resin solution, gelcoat, and organic peroxide catalyst (oxidizer) in spraying areas that contained overhead lights with exposed bulbs. The lights were located approximately 12 feet, up to approximately 15 feet, from the spraying surfaces and many contained deposits of accumulated splatter and residues.
Recent events (3)
  • — F (S) $7000
  • — C (S) $6300
  • — Z (S) $6300

1910.132 A

Serious Gravity 5 4 instances 7 exposed
Issued
Dec 17, 2012
Abate by
May 20, 2013
Penalty
Initial $4,500 · Current $4,400 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:    (a) Stock Tank Area: On or about August 14, 2012, and at times prior thereto, employees were exposed to dermal hazards associated with applying chopped fiberglass. The employer did not require the use of adequate personal protective equipment to reduce skin exposure.     (b) Stock Tank Area: On or about August 14, 2012, and at times prior thereto, employees were exposed to dermal hazards associated with applying chemicals such as, but not limited to, styrene and methyl ethyl ketone peroxide. The employer did not require the use of adequate personal protective equipment to reduce skin exposure.        (c) Tank Production Area: On or about August 14, 2012, and at times prior thereto, employees were exposed to dermal hazards associated with applying chopped fiberglass. The employer did not require the use of adequate personal protective equipment to reduce skin exposure.     (d) Tank Production Area: On or about August 14, 2012, and at times prior thereto, employees were exposed to dermal hazards associated with applying chemicals such as, but not limited to, styrene and methyl ethyl ketone peroxide. The employer did not require the use of adequate personal protective equipment to reduce skin exposure.
Recent events (3)
  • — F (S) $4400
  • — C (S) $4500
  • — Z (S) $4500

1910.133 A01

Serious Gravity 1 2 instances 7 exposed
Issued
Dec 17, 2012
Abate by
May 20, 2013
Penalty
Initial $2,700 · Current $2,600 Reduced
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment:    (a) Stock Tank Area: On or about August 14, 2012, and at times prior thereto, employees were exposed to eye injuries associated with spraying resin solution and organic peroxide catalyst (oxidizer) which contain chemicals such as, but not limited to, styrene and methyl ethyl ketone peroxide. The employer did not require the use of adequate personal protective equipment to reduce eye exposure.      (b) Tank Production Area: On or about August 14, 2012, and at times prior thereto, employees were exposed to eye injuries associated with spraying resin solution and organic peroxide catalyst (oxidizer) which contain chemicals such as, but not limited to, styrene and methyl ethyl ketone peroxide. The employer did not require the use of adequate personal protective equipment to reduce eye exposure.
Recent events (3)
  • — F (S) $2600
  • — C (S) $2700
  • — Z (S) $2700

1910.151 C

Serious Gravity 1 2 instances 7 exposed
Issued
Dec 17, 2012
Abate by
May 20, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    (a) Stock Tank Area: On or about August 14, 2012, and at times prior thereto, employees were exposed to eye injuries while spraying resin solution and organic peroxide catalyst (oxidizer) which contain chemicals such as, but not limited to, styrene and methyl ethyl ketone peroxide. The employer did not provide employees with a suitable eye wash station.     (b) Tank Production Area: On or about August 14, 2012, and at times prior thereto, employees were exposed to eye injuries while spraying resin solution and organic peroxide catalyst (oxidizer) which contain chemicals such as, but not limited to, styrene and methyl ethyl ketone peroxide. The employer did not provide employees with a suitable eye wash station.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.146 D05 I

Serious Gravity 10 1 instance 5 exposed
Issued
Dec 17, 2012
Abate by
May 20, 2013
Penalty
Initial $6,300 · Current $1,750 Reduced
29 CFR 1910.146(d)(5)(i): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not evaluate permit space conditions when entry operations were conducted by testing conditions in the permit space to determine if acceptable entry conditions existed before entry was authorized to begin:     (a) Tank Production Area: On or about August 14, 2012, and at times prior thereto, employees were exposed to fire, explosion, acute illness, and/or oxygen deficient atmospheres while fabricating fiberglass tanks from within without having the tanks effectively tested prior to entry.
Recent events (3)
  • — F (S) $1750
  • — C (S) $6300
  • — Z (S) $6300

1910.146 G01

Serious Gravity 10 1 instance 4 exposed
Issued
Dec 17, 2012
Abate by
May 20, 2013
Penalty
Initial $6,300 · Current $1,750 Reduced
29 CFR 1910.146(g)(1): The employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146:    (a) Tank Production Area: On or about August 14, 2012, and at times prior thereto, employees were exposed to fire, explosion, acute illness, and/or oxygen deficient atmospheres while fabricating fiberglass tanks from within. The employer did not ensure employees were provided with adequate training regarding the hazards of confined space entry.
Recent events (3)
  • — F (S) $1750
  • — C (S) $6300
  • — Z (S) $6300

1910.146 D09

Serious Gravity 10 1 instance 4 exposed
Issued
Dec 17, 2012
Abate by
May 20, 2013
Penalty
Initial $6,300 · Current $1,750 Reduced
29 CFR 1910.146(d)(9): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement procedures for summoning rescue and emergency services, for rescuing entrants from permit spaces, for providing necessary emergency services to rescued employees, and for preventing unauthorized personnel from attempting a rescue:     (a) Tank Production Area: On or about August 14, 2012, and at times prior thereto, employees were exposed to fire, explosion, acute illness, and/or oxygen deficient atmospheres while fabricating fiberglass tanks from within. The employer did not ensure employees were provided with emergency personnel and procedures to rescue entrants in the event entrants could not perform a self rescue.
Recent events (3)
  • — F (S) $1750
  • — C (S) $6300
  • — Z (S) $6300

1910.146 D10

Serious Gravity 10 1 instance 5 exposed
Issued
Dec 17, 2012
Abate by
May 20, 2013
Penalty
Initial $6,300 · Current $1,750 Reduced
29 CFR 1910.146(d)(10): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement a system for the preparation, issuance, use, and cancellation of entry permits as required by this section:     (a) Tank Production Area: On or about August 14, 2012, and at times prior thereto, employees were exposed to fire, explosion, acute illness, and/or oxygen deficient atmospheres while fabricating fiberglass tanks from within without utilizing entry permits prior to entry.
Recent events (3)
  • — F (S) $1750
  • — C (S) $6300
  • — Z (S) $6300

1910.242 B

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 17, 2012
Abate by
May 20, 2013
Penalty
Initial $5,400 · Current $7,000
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    (a) Production Area: On or about August 14, 2012, and at times prior thereto, employees were exposed to air embolisms while using compressed air nozzles with approximately 86 p.s.i. of air at the nozzle to clean floors and blow off their skin and clothes of dust and debris.
Recent events (3)
  • — F (S) $7000
  • — C (S) $5400
  • — Z (S) $5400

1910.305 B02 I

Serious Gravity 10 1 instance 9 exposed
Issued
Dec 17, 2012
Abate by
May 20, 2013
Penalty
Initial $12,600 · Current $7,000 Reduced
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    (a) Stock Tank Area: On or about August 16, 2012, and at times prior thereto, employees were exposed to fire and explosion hazards due to energized wires not contained within in a cover. The wires protruded out of the electrical fitting and were located approximately 7 feet overhead from drums and tanks of flammable resin.     L.F. MANUFACTURING, INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 310992375, CITATION NUMBER 01, ITEM NUMBER 05, ISSUED ON JUNE 30, 2009, AND CONFIRMED AS A FINAL ORDER ON AUGUST 17, 2009 WITH RESPECT TO A WORKPLACE LOCATED AT 2450 INDUSTRIAL BLVD, WAYCROSS, GEORGIA, 31503.
Recent events (3)
  • — F (S) $7000
  • — C (R) $12600
  • — Z (R) $12600

View L.F. Manufacturing, INC.'s full OSHA safety record →