Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NATIONAL PARK SERVICE NORTH CASCADES, NEWHALEM CAMP TENDER in STATE ROUTE 20, NEWHALEM, WA 98283 (NAICS 712190). OSHA activity number 335740007.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch National Park Service North Cascades, Newhalem Camp Tender — free Get an email when a new federal OSHA severe-injury report for National Park Service North Cascades, Newhalem Camp Tender is published. One employer, no account, unsubscribe in one click.
Site address
STATE ROUTE 20
City
NEWHALEM
State
WA
ZIP
98283
Mailing
810 STATE ROUTE 20, SEDRO WOOLLEY, WA 98284
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
712190
Employees
1
Ownership type
D

4 citations on file for this inspection.

1910.303 B02

Other-than-serious 1 instance 1 exposed
Issued
Aug 30, 2012
Abate by
Oct 15, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling:     a) Tender Room, where an orange extension cord and a relocatable power tap were daisy chained and used to supply power to the telephone located in the communication cabinet.
Recent events (1)
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 1 exposed
Issued
Aug 30, 2012
Abate by
Oct 15, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for the fixed wiring of a structure:    a) Tender Room, where an orange extension cord was used to supply power to a relocatable power tap and the telephone located in the communication cabinet.
Recent events (1)
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 1 instance 1 exposed
Issued
Aug 30, 2012
Penalty
Initial $0 · Current $0
1910.303(g)(1)(ii): Working space for equipment likely to require examination, adjustment, servicing, or maintenance while energized was used for storage:     a) Tender Room, where items including a desk and chairs were stored in front of circuit panels M and N.
Recent events (1)
  • — Z (O) $0

1910.305 J01 I

Other-than-serious 1 instance 1 exposed
Issued
Aug 30, 2012
Abate by
Oct 15, 2012
Penalty
Initial $0 · Current $0
29CFR1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles may have no live parts normally exposed to employee contact. However, rosettes and cleat-type lampholders and receptacles located at least 2.44 m (8.0 ft) above the floor may have exposed terminals:    a) Tender Room, where the light fixtures located 7 feet 6 inches above floor level were equipped with  unguarded single bulbs.
Recent events (1)
  • — Z (O) $0

View National Park Service North Cascades, Newhalem Camp Tender's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335740007.