Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: DAY LUMBER & PALLET, LLC

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of DAY LUMBER & PALLET, LLC in 108 REBECCA WALDRON ROAD, DOUGLAS, GA 31535 (NAICS 321920). OSHA activity number 335742581.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch DAY Lumber & Pallet, LLC for free Get an email when a new federal OSHA severe-injury report for DAY Lumber & Pallet, LLC is published. One employer, no account, unsubscribe in one click.
Site address
108 REBECCA WALDRON ROAD
City
DOUGLAS
State
GA
ZIP
31535
Mailing
108 REBECCA WALDRON ROAD, DOUGLAS, GA 31535
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
11
Ownership type
Private (A)

4 citations on file for this inspection.

1910.212 A05

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 27, 2012
Abate by
Oct 19, 2012
Penalty
Initial $1,360 · Current $680 Reduced
29 CFR 1910.212(a)(5):     Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch:    a) In the pallet repair shop near the center workstation, on or about August 15, 2012 and at times prior to, the pedestal fan was not adequately guarded, in that the fan blade guard had a four-inch diameter opening, resulting in a struck-by hazard.    ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
  • · I (S) $680
  • · Z (S) $1360

1910.303 G02 II

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 27, 2012
Abate by
Oct 19, 2012
Penalty
Initial $1,020 · Current $510 Reduced
29 CFR 1910.303(g)(2)(ii):     In locations where electric equipment was likely to be exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage:    a) At the electrical control box for the notcher, on or about August 15, 2012 and at times prior to, two sections of flexible conduit had separated from the box, which exposed the insulated electrical conductors that were supposed to be housed inside the conduit to physical damage, resulting in an electrical hazard.    ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
  • · I (S) $510
  • · Z (S) $1020

1910.305 B01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 27, 2012
Abate by
Oct 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(i):     Openings through which conductors enter boxes, cabinets, or fittings were not effectively closed    a) At the electrical control box for the notcher, on or about August 15, 2012 and at times prior to, two sections of flexible conduit were separated from the box, which left the openings through which the conductors entered the box ineffectively closed, resulting in an electrical hazard.    ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.95 G06

Other-than-serious 2 instances 2 exposed
Issued
Sep 27, 2012
Penalty
Initial $0 · Current $0

Hazardous substances 8111

29 CFR 1910.95(g)(6):     At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels:    a) In the pallet repair shop, on or about August 15, 2012, annual audiometric testing was not provided for a nail gun operator who was exposed to noise at 132% of the action level (8-hour time-weighted average sound level of 85 dBA) or an equivalent sound level of 87.0 dBA during the 346 minute sampling period, resulting in a noise hazard.  The exposure calculation included a zero increment for the 134 minutes not sampled.    b) In the pallet repair shop, on or about August 15, 2012, annual audiometric testing was not provided for a nail gun operator who was exposed to noise at 167% of the action level (8-hour time-weighted average sound level of 85 dBA) or an equivalent sound level of 88.6 dBA during the 431 minute sampling period, resulting in a noise hazard.  The exposure calculation included a zero increment for the 49 minutes not sampled.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View DAY Lumber & Pallet, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335742581.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.