BUFFALO, NY —
OSHA Inspection: PRIOR AVIATION SERVICE INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PRIOR AVIATION SERVICE INC. in 50 NORTH AIRPORT DRIVE, BUFFALO, NY 14225 (NAICS 488190). OSHA activity number 335742797.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PRIOR AVIATION SERVICE INC.
- Site address
- 50 NORTH AIRPORT DRIVE
- City
- BUFFALO
- State
- NY
- ZIP
- 14225
- Mailing
- 50 NORTH AIRPORT DRIVE, BUFFALO, NY 14225
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488190
- Employees
- 160
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.107 B09
- Issued
- Sep 17, 2012
- Penalty
- Initial $3,060 · Current $0 Reduced
General-duty citation text
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction: a) On or about 08/15/12, in Hangar 2/Spray booth area, a cardboard box was stored against the JBI spray booth's wall and approximately 16 inches from spray booth's edge, there was a brown paper covered table with a U-Line Kraft Paper Roll on it. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $3060
1910.107 B03
- Issued
- Sep 17, 2012
- Penalty
- Initial $3,060 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.107(b)(3): The floor surface of a spray booth and operator's working area, if combustible, shall be covered with noncombustible material of such character as to facilitate the safe cleaning and removal of residues. a) On or about 08/15/12, in Hanger 2 Spray room, Operator's working area had combustible materials inside the spray booth such as: U-Line Kraft paper/brown paper used to cover spray booth's surfaces and a wooden piece. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2000
- — Z (S) $3060
1910.107 C06
- Issued
- Sep 17, 2012
- Abate by
- Oct 17, 2012
- Penalty
- Initial $3,060 · Current $0 Reduced
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: a) On or about 08/15/12, in Hangar 2/Spray booth area, a General Duty 240 VAC Electrical Disconnect Switch for Paint Booth Exhaust Fan was located less than 3 feet from open-face spray booth edge. Distance from open-face booth edge to electrical disconnect switch's border was 29.5 inch, and distance from open-face booth edge to disconnect switch's conduit was 34 inch. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $3060
1910.107 B05 IV
- Issued
- Sep 17, 2012
- Abate by
- Oct 17, 2012
- Penalty
- Initial $3,060 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: a) On or about 08/15/12, in Hangar 2, an automatic fire extinguisher: Kidde Mariner Fyre Watch FW200-FM200, was mounted on a wall away from the spray booth's open-face and it was not interconnected by means of a piping network to protect the interior of the spray booth and the exhaust ductwork. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2000
- — Z (S) $3060
1910.305 B02 I
- Issued
- Sep 17, 2012
- Penalty
- Initial $3,060 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: a) On or about 08/15/12, in Hangar 2/Spray area, an electrical junction box energizing lights inside of the spray booth and lights for spray room did not have a cover. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (S) $3060
1910.212 B
- Issued
- Sep 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) On or about 08/15/12, in Hangar 1, a DoAll Vertical Band Saw, Model 2013 V, Serial #457-891346 was not anchored to floor. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Prior Aviation Service INC.
View Prior Aviation Service INC.'s full OSHA safety record →
More inspections in this industry (NAICS 488190)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335742797.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.