CINCINNATI, OH ·
OSHA Inspection: RICARDO CHOC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RICARDO CHOC in 2372 HARRYWOOD CT., CINCINNATI, OH 45239 (NAICS 238160). OSHA activity number 335769188.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RICARDO CHOC
- Site address
- 2372 HARRYWOOD CT.
- City
- CINCINNATI
- State
- OH
- ZIP
- 45239
- Mailing
- 23335 N. 91ST ST., SCOTTSDALE, AZ 85255
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.20 B02
- Issued
- Aug 22, 2012
- Abate by
- Oct 4, 2012
- Penalty
- Initial $1,600 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): Programs did not provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers: - Site inspections were not conducted by a competent person in that employees were working on the roof of a residential structure while not using any type of fall protection system. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- · I (S) $1000
- · Z (S) $1600
1926.300 B02
- Issued
- Aug 22, 2012
- Penalty
- Initial $1,200 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.300(b)(2): Belts, gears, shafts, pulleys, sprockets, spindles, drums, fly wheels, chains, or other reciprocating, rotating or moving parts of equipment shall be guarded if such parts are exposed to contact by employees or otherwise create a hazard. Guarding shall meet the requirements as set forth in American National Standards Institute, B15.1-1953 (R1958), Safety Code for Mechanical Power-Transmission Apparatus: -The Ridgid brand air compressor was missing the guard that covered the 10" and 4" pulleys, exposing employees to at least two in-running nip points.
Recent events (2)
- · I (S) $1000
- · Z (S) $1200
1926.501 B13
- Issued
- Aug 22, 2012
- Penalty
- Initial $2,800 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems: - Employees were roofing a residential structure while not using adequate fall protection systems. Potential fall height was measured to be 19' with a roof pitch of 7/12.
Recent events (2)
- · I (S) $1000
- · Z (S) $2800
More inspections in this industry (NAICS 238160)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335769188.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.