SAN ANTONIO, TX ·
OSHA Inspection: RIDDELL ALL-AMERICAN SPORTS
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of RIDDELL ALL-AMERICAN SPORTS in 6846 ALAMO DOWNS PKWY, SAN ANTONIO, TX 78230 (NAICS 451110). OSHA activity number 335774188.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RIDDELL ALL-AMERICAN SPORTS
- Site address
- 6846 ALAMO DOWNS PKWY
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78230
- Mailing
- 6846 ALAMO DOWNS PKWY, SAN ANTONIO, TX 78230
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 451110
- Employees
- 1000
- Ownership type
- A
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 17, 2013
- Abate by
- Jan 22, 2013
- Penalty
- Initial $7,000 · Current $5,600 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of falls. On or about 8/16/12, employees were exposed to a fall from height of approximately 10 ft, while using a industrial powered truck with lift basket attachment without proper fall protection in the course of their normal duties to store material in the warehouse of the San Antonio Plant.
Recent events (2)
- · I (S) $5600
- · Z (S) $7000
1910.132 D01
- Issued
- Jan 17, 2013
- Abate by
- Feb 1, 2013
- Penalty
- Initial $6,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): On or about 8/16/2012, employees were exposed to an inhalation hazard while spraying paint with chemicals including Methyl Ethyl Ketone and Propylene Glycol Methyl Ether without atmospheric to determine what type of PPE would be required.
Recent events (2)
- · I (S) $0
- · Z (S) $6000
1910.134 C02 II
- Issued
- Jan 17, 2013
- Abate by
- Jan 22, 2013
- Penalty
- Initial $3,000 · Current $2,400 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: On or about 8/16/12, employees were exposed to inhalation hazards by not providing personnel voluntarily wearing respirators with medical evaluations from a physician nor were they instructed on proper care, cleaning and maintenance to ensure the respirators themselves would not be a hazard.
Recent events (2)
- · I (S) $2400
- · Z (S) $3000
1910.178 L06
- Issued
- Jan 17, 2013
- Abate by
- Jan 22, 2013
- Penalty
- Initial $5,000 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated as required by this paragraph (l): On or about 8/16/12, the shipping department where employees operated an electric Crown Standup Counterbalanced Truck was exposed to a caught-in and struck-by hazard by not properly being certified and evaluated in the use of a powered industrial truck. Employees utilize the counterbalanced truck to constantly store product and raw material during the course of normal operations.
Recent events (2)
- · I (S) $4000
- · Z (S) $5000
1910.217 B04 I
- Issued
- Jan 17, 2013
- Abate by
- Feb 1, 2013
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.217(b)(4)(i): Pedal mechanism on mechanical power press full revolution clutches were not protected to prevent unintended operation from falling or moving objects or by accidental stepping onto the pedals: On or about 8/16/12, employees were exposed to a caught in hazard by not properly guarding the foot pedal of an industrial power press in the helmet repair section.
Recent events (2)
- · I (S) $0
- · Z (S) $7000
1910.219 D01
- Issued
- Jan 17, 2013
- Abate by
- Jan 22, 2013
- Penalty
- Initial $5,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulleys with parts seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): On or about 8/16/2012, main work area, where the pulley for the sewing machines did not employ a guard exposing employees to a caught-in hazard. Equipment utilized: a)Juki DDL-555, no serial b)Singer, no model or serial plate c)Singer, no model or serial plate
Recent events (2)
- · I (S) $0
- · Z (S) $5000
1910.242 B
- Issued
- Jan 17, 2013
- Abate by
- Jan 22, 2013
- Penalty
- Initial $4,000 · Current $3,200 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: On or about 8/16/12, employees were exposed to a struck by hazard while utilizing compressed air above 60 p.s.i. in the helmet repair area, where compressed air was used to clean helmets.
Recent events (2)
- · I (S) $3200
- · Z (S) $4000
1910.303 G02 I
- Issued
- Jan 17, 2013
- Abate by
- Jan 22, 2013
- Penalty
- Initial $7,000 · Current $5,600 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): On or about 8/16/12, in the Southwest section of the warehouse, employees were exposed to an electrical hazard where the ice machine did not employ a protective cover to prevent employees from accidental electric shock while walking in and around the area.
Recent events (2)
- · I (S) $5600
- · Z (S) $7000
More inspections in this industry (NAICS 451110)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335774188.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.