Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: KENNEBEC SCRAP IRON, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KENNEBEC SCRAP IRON, INC. in 48 BROOMHANDLE ROAD, OAKLAND, ME 04963 (NAICS 423930). OSHA activity number 335784989.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kennebec Scrap Iron, INC. for free Get an email when a new federal OSHA severe-injury report for Kennebec Scrap Iron, INC. is published. One employer, no account, unsubscribe in one click.
Site address
48 BROOMHANDLE ROAD
City
OAKLAND
State
ME
ZIP
04963
Mailing
48 BROOMHANDLE ROAD, OAKLAND, ME 04963
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
5
Ownership type
Private (A)

4 citations on file for this inspection.

1910.22 D01

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 22, 2012
Abate by
Aug 25, 2012
Penalty
Initial $1,360 · Current $816 Reduced
29 CFR 1910.22(d)(1):  In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official shall be marked on plates of approved design which shall be supplied and securely affixed by the owner of the building, or his duly authorized agent, in a conspicuous place in each space to which they relate. Such plates shall not be removed or defaced but, if lost, removed, or defaced, shall be replaced by the owner or his agent.    Shop, Second Floor Storage Area - The employer did not have a structural load rating posted for the second floor level.
Recent events (2)
  • · I (S) $816
  • · Z (S) $1360

1910.23 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 22, 2012
Abate by
Aug 25, 2012
Penalty
Initial $1,360 · Current $816 Reduced
29 CFR 1910.23(c)(1):  Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The railing shall be provided with a toeboard wherever, beneath the open sides:    Shop, Second Floor Storage Area -  The employer did not install a guard rail system to prevent possible falls of approximately 10 feet to the lower level.
Recent events (2)
  • · I (S) $816
  • · Z (S) $1360

1910.253 B02 II

Serious Gravity 5 2 instances 5 exposed
Issued
Aug 22, 2012
Abate by
Aug 25, 2012
Penalty
Initial $1,700 · Current $1,020 Reduced
29 CFR 1910.253(b)(2)(ii):   Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 (6.1 m) feet from highly combustible materials such as oil or excelsior. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:    Shop:      Instance A - One cylinder of oxygen was stored two feet from a cylinder of propane.  Instance B - Two cylinders of combustible gas were not secured and protected from damage.
Recent events (2)
  • · I (S) $1020
  • · Z (S) $1700

1910.305 B02 I

Serious Gravity 1 1 instance 5 exposed
Issued
Aug 22, 2012
Abate by
Aug 25, 2012
Penalty
Initial $1,020 · Current $612 Reduced
29 CFR 1910.305(b)(2)(i):  All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy:    Shop - The light switch had exposed live wires due to a missing face plate.
Recent events (2)
  • · I (S) $612
  • · Z (S) $1020

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335784989.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.