Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: L. HERNANDEZ CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of L. HERNANDEZ CONSTRUCTION, INC. in 608 W. 27TH., HOUSTON, TX 77008 (NAICS 238170). OSHA activity number 335791786.

Watch L. Hernandez Construction, INC. — free Get an email when a new federal OSHA severe-injury report for L. Hernandez Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
608 W. 27TH.
City
HOUSTON
State
TX
ZIP
77008
Mailing
21726 TOPHILL, SPRING, TX 77388
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
22
Ownership type
A

3 citations on file for this inspection.

1926.451 G01 VII

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(g)(1)(vii):  Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    The employer does not protect employees from falling when working more than 10 feet above a lower level on a scaffold.  This violation was observed on or about August 14, 2012, on a pump jack scaffold at the job site where employees were exposed to a 30 foot fall hazard when working from the scaffold.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $2800

1926.452 J01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.452(j)(1):  Pump jack brackets, braces, and accessories were not fabricated from metal plates and angles. Each pump jack bracket did not have two positive gripping mechanisms to prevent any failure or slippage.     The employer does not ensure that pump jack scaffold braces are fabricated from metal plates.  This violation was observed on or about August 14, 2012, on the west side of the structure where an employee was exposed to a fall hazard while working from a pump jack scaffold that had plywood bracing.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $2800

1926.452 J02

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.452(j)(2):  Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.    The employer does not provide bracing to the bottom of pump jack scaffolds.  This violation was observed on or about August 14, 2012, on the west side of the structure where an employee was exposed to a fall hazard while working from a pump jack scaffold did not have bracing at the bottom of the scaffold, below the working surface
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335791786.