DALLAS, TX ·
OSHA Inspection: TEXAS BY-PRODUCTS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TEXAS BY-PRODUCTS in 515 PONTIAC STREET, DALLAS, TX 75203 (NAICS 311613). OSHA activity number 335799599.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TEXAS BY-PRODUCTS
- Site address
- 515 PONTIAC STREET
- City
- DALLAS
- State
- TX
- ZIP
- 75203
- Mailing
- 515 PONTIAC STREET, DALLAS, TX 75203
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311613
- Employees
- 23
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.22 C
- Issued
- Oct 2, 2012
- Abate by
- Oct 10, 2012
- Penalty
- Initial $2,400 · Current $1,440 Reduced
General-duty citation text
29 CFR 1910.22(c): Covers and/or guardrails were not provided to protect personnel from the hazards of open pits, tanks, vats, ditches, etc.: On or about August 14, 2012 and times prior thereto, employees operated a screw conveyor system inside a large waste transfer pit that was not guarded to prevent employees from down into the pit.
Recent events (2)
- · I (S) $1440
- · Z (S) $2400
1910.23 D01 III
- Issued
- Oct 2, 2012
- Abate by
- Oct 10, 2012
- Penalty
- Initial $2,400 · Current $1,440 Reduced
General-duty citation text
29 CFR 1910.23(d)(1)(iii): Stairway(s) less than 44 inches wide having both sides open, did not have one stair railing on each side: On or about August 14, 2012 and times prior thereto, employees used metal stairs to gain access to a waste pit, the stairs did not have hand rails installed on both open sides to prevent accidental falls off stairs.
Recent events (2)
- · I (S) $1440
- · Z (S) $2400
1910.147 C01
- Issued
- Oct 2, 2012
- Abate by
- Oct 10, 2012
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. On or about August 14, 2012 and times prior thereto, the employer had not developed an energy control program for employees who performed servicing and maintenance work on equipment and machinery and were not protected from the unexpected engizing, start up or released or stored energy.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.305 G01 III
- Issued
- Oct 2, 2012
- Abate by
- Oct 10, 2012
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iii): Flexible cords and cables were used for purposes prohibited by subparagraphs (A) through (E) of this paragraph: On or about August 14, 2012 and times prior thereto, employees used an orange flexible cord that was ran through a brick wall to supply electrical power to an outside sump pump.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1910.1200 E01
- Issued
- Oct 2, 2012
- Abate by
- Oct 10, 2012
- Penalty
- Initial $2,400 · Current $1,440 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following: On or about August 14, 2012 and times prior thereto, the employer did not develop a Hazard Communication Program for employees using hazardous chemicals, such as but not limited to Rust-Oleum enamel paints, Pro-Chem cleaning system degreasers, oils, lubricatants, and antifreeze.
Recent events (2)
- · I (S) $1440
- · Z (S) $2400
More inspections in this industry (NAICS 311613)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335799599.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.