Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: TEXAS BY-PRODUCTS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TEXAS BY-PRODUCTS in 515 PONTIAC STREET, DALLAS, TX 75203 (NAICS 311613). OSHA activity number 335799599.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Texas By-Products for free Get an email when a new federal OSHA severe-injury report for Texas By-Products is published. One employer, no account, unsubscribe in one click.
Establishment
TEXAS BY-PRODUCTS
Site address
515 PONTIAC STREET
City
DALLAS
State
TX
ZIP
75203
Mailing
515 PONTIAC STREET, DALLAS, TX 75203
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311613
Employees
23
Ownership type
Private (A)

5 citations on file for this inspection.

1910.22 C

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 2, 2012
Abate by
Oct 10, 2012
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1910.22(c): Covers and/or guardrails were not provided to protect personnel from the hazards of open pits, tanks, vats, ditches, etc.:    On or about  August 14, 2012 and times prior thereto, employees operated a screw conveyor system inside a large waste transfer pit that was not guarded to prevent employees from down into the pit.
Recent events (2)
  • · I (S) $1440
  • · Z (S) $2400

1910.23 D01 III

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 2, 2012
Abate by
Oct 10, 2012
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1910.23(d)(1)(iii): Stairway(s) less than 44 inches wide having both sides open, did not have one stair railing on each side:    On or about August 14,  2012 and times prior thereto, employees used metal stairs to gain access to a waste pit, the stairs did not have hand rails installed on both open sides to prevent accidental falls off stairs.
Recent events (2)
  • · I (S) $1440
  • · Z (S) $2400

1910.147 C01

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 2, 2012
Abate by
Oct 10, 2012
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.    On or about August 14,  2012 and times prior thereto, the employer had not developed an energy control program for employees who performed servicing and maintenance work on equipment and machinery and were not protected from the unexpected engizing, start up or released or stored energy.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1910.305 G01 III

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 2, 2012
Abate by
Oct 10, 2012
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.305(g)(1)(iii):   Flexible cords and cables were used for purposes prohibited by subparagraphs (A) through (E) of this paragraph:    On or about August 14,  2012 and times prior thereto, employees used an orange  flexible cord that was ran through a brick wall to supply electrical power to an outside sump pump.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1910.1200 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 2, 2012
Abate by
Oct 10, 2012
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:    On or about August 14, 2012 and times prior thereto, the employer did not develop a Hazard Communication Program for employees using hazardous chemicals, such as but not limited to Rust-Oleum enamel paints, Pro-Chem cleaning system degreasers, oils, lubricatants, and antifreeze.
Recent events (2)
  • · I (S) $1440
  • · Z (S) $2400

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335799599.