Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: WAYNE J. GRIFFIN ELECTRIC, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WAYNE J. GRIFFIN ELECTRIC, INC in 150 RIVERMEAD RD, PETERBOROUGH, NH 03458 (NAICS 238210). OSHA activity number 335801585.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wayne J. Griffin Electric, INC for free Get an email when a new federal OSHA severe-injury report for Wayne J. Griffin Electric, INC is published. One employer, no account, unsubscribe in one click.
Site address
150 RIVERMEAD RD
City
PETERBOROUGH
State
NH
ZIP
03458
Mailing
116 HOPPING BROOK RD., HOLLISTON, MA 01746
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
1000
Ownership type
Private (A)

5 citations on file for this inspection.

1926.21 B02

Deleted Serious Gravity 5 3 instances 3 exposed
Issued
Nov 23, 2012
Abate by
Dec 19, 2012
Penalty
Initial $5,500 · Current $0 Reduced
29 CFR 1926.21(b)(2):  The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:    Jobsite:  Employees were not properly trained in the recognition of excavation hazards and the applicable regulations to control or eliminate them.
Recent events (2)
  • · I (S) $0
  • · Z (S) $5500

1926.651 C02

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Nov 23, 2012
Abate by
Dec 3, 2012
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1926.651(c)(2):  A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:    Jobsite:  On or about June 19 and 20, 2012, employees, working in the trench, while installing conduit, were not provided with a safe means of egress within 25 feet.
Recent events (2)
  • · I (S) $0
  • · Z (S) $7000

1926.652 A01

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Nov 23, 2012
Abate by
Dec 3, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.652(a)(1):  Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c).     Jobsite: On or about June 19 and 20, 2010, the employees, installing PVC conduit in the unprotected trench, were exposed to the hazard of cave-ins.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.651 J02

Other-than-serious 1 instance 3 exposed
Issued
Nov 23, 2012
Abate by
Dec 3, 2012
Penalty
Initial $7,000 · Current $1,000 Reduced
29 CFR 1926.651(j)(2):  Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.    Jobesite:  On or about June 19 and 20, 2012, spoil piles were located directly on the edge of the trench where employees were engaged in installing PVC conduit in the trench.
Recent events (2)
  • · I (O) $1000
  • · Z (S) $7000

1926.651 K01

Other-than-serious 2 instances 3 exposed
Issued
Nov 23, 2012
Abate by
Dec 3, 2012
Penalty
Initial $5,500 · Current $0 Reduced
29 CFR 1926.651(k)(1):  An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift.    Jobsite:  On or about June 19 and 20, 2010, the competent person did not conduct a proper inspection of the trench, prior to the start of work or as needed, where employees were installing PVC conduit.
Recent events (2)
  • · I (O) $0
  • · Z (S) $5500

View Wayne J. Griffin Electric, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335801585.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.