Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VALUE SERVICES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VALUE SERVICES in 10208 S. KNOLL CT, HIGHLANDS RANCH, CO 80130 (NAICS 236115). OSHA activity number 335809398.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Value Services — free Get an email when a new federal OSHA severe-injury report for Value Services is published. One employer, no account, unsubscribe in one click.
Establishment
VALUE SERVICES
Site address
10208 S. KNOLL CT
City
HIGHLANDS RANCH
State
CO
ZIP
80130
Mailing
1175 KEN CARL AVE, UNIT F 243, LITTLETON, CO 80127
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
3
Ownership type
A

7 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 12, 2012
Abate by
Sep 17, 2012
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.451(b)(1):  Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports:    (a)  On or about August 17, 2012, and at times prior, an employee was not protected from fall hazards in that the scaffold he was using was not fully planked on the north side of a house under construction.     Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.451 F03

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Sep 12, 2012
Abate by
Sep 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(3):  Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:    (a)  On or about August 17, 2012, and at times prior, the scaffold used while building a house was not inspected prior to each shift that employees worked on the scaffold.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 A

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Sep 12, 2012
Abate by
Sep 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a):  The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:    (a)  On or about August 17, 2012, and at times prior, the employer had not trained the employee using the scaffold while building a house to recognize and minimize the hazards of working from scaffolds.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 12, 2012
Abate by
Sep 17, 2012
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.451(e)(1):  When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, strucure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access:    (a)  On or about August 17, 2012, and at times prior, an employee climbed the crossbraces to access the scaffold.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.451 G01 VII

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 12, 2012
Abate by
Sep 17, 2012
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.451(g)(1)(vii):  Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:    (a)  On or about August 17, 2012, and at times prior, an employee was not protected from fall hazards in that the ends of the scaffold levels that were 10 feet and more above the ground, did not have guardrails.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 12, 2012
Abate by
Sep 17, 2012
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.501(b)(13):  Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b):     (a)  On or about August 17, 2012, and at times prior, an employee was installing soffits on a second level roof while standing on a closed step ladder while on the first level roof, which had eaves 11 feet above the ground, without fall protection.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.1053 B04

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 12, 2012
Abate by
Sep 17, 2012
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:    (a)  On or about August 17, 2012, and at times prior, an employee was exposed to fall hazards when he used a closed step ladder on a sloped roof in order to install soffits on a higher level roof.        Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335809398.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.