On , OSHA opened a planned safety inspection of GIBSON MAINTENANCE in 3033 PASCAGOULA STREET, PASCAGOULA, MS 39563 (NAICS 236220). OSHA activity number 335809430.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GIBSON MAINTENANCE
- Site address
- 3033 PASCAGOULA STREET
- City
- PASCAGOULA
- State
- MS
- ZIP
- 39563
- Mailing
- 118 DENNIS LANE, LONG BEACH, MS 39560
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 11
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1926.300 B05
- Issued
- Aug 31, 2012
- Abate by
- Sep 4, 2012
- Penalty
- Initial $1,600 · Current $750 Reduced
General-duty citation text
29 CFR 1926.300(b)(5): "Exposure of blades." When the periphery of the blades of a fan is less than 7 feet (2.128 m) above the floor or working level, the blades shall be guarded. The guard shall have openings no larger than 1/2 inch (1.27 cm). (a) Job Site - On or about August 16, 2012 a fabricated box fan use to circulate air in the work area had a guard with opening 4 inches by 2 inches, thereby, exposing employees to the hazard of being struck by the blades.
Recent events (2)
- · I (S) $750
- · Z (S) $1600
1926.405 G02 III
- Issued
- Aug 31, 2012
- Abate by
- Sep 4, 2012
- Penalty
- Initial $1,600 · Current $750 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iii): Splices. Flexible cords shall be used only in continuous lengths without splice or tap. Hard service flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced. (a) Job Site - On or about August 16, 2012 a flexible cord supplying electricity to a fabricated box fan in the work area was spliced.
Recent events (2)
- · I (S) $750
- · Z (S) $1600
1926.451 B01
- Issued
- Aug 31, 2012
- Abate by
- Sep 4, 2012
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: (a) Job Site - On or about August 16, 2012 employees were working on scaffolding that was not fully decked.
Recent events (2)
- · I (S) $0
- · Z (S) $1200
1926.451 C02
- Issued
- Aug 31, 2012
- Abate by
- Sep 4, 2012
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation. (a) Job Site - On or about August 16, 2012 employees were exposed to a fal hazard while painting from scaffold that did not rest on base plates.
Recent events (2)
- · I (S) $0
- · Z (S) $1200
1926.20 B01
- Issued
- Aug 31, 2012
- Abate by
- Sep 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.20(b)(1): It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part. (a) Job Site - On or about August 16, 2012 the employer had not developed a safety and health program for employees exposed to construction hazards.
Recent events (1)
- · Z (O) $0
1910.1200 E01
- Issued
- Aug 31, 2012
- Abate by
- Sep 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met, and which also includes the following: (a) Jod Site - On or about August 16, 2012 the employer had not developed, implemented and documented a written hazard communication program at the worksite for employee using paints.
Recent events (1)
- · Z (O) $0