OSHA Inspection: LYMO CONSTRUCTION COMPANY, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of LYMO CONSTRUCTION COMPANY, INC. in 206 HEATER RD., LEBANON, NH 03766 (NAICS 238170). OSHA activity number 335827804.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lymo Construction Company, INC. — free Get an email when a new federal OSHA severe-injury report for Lymo Construction Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
206 HEATER RD.
City
LEBANON
State
NH
ZIP
03766
Mailing
25 COLUMBIA CIRCLE, MERRIMACK, NH 03054
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
20
Ownership type
A

3 citations on file for this inspection.

1926.502 D16 II

Other-than-serious 1 instance 1 exposed
Issued
Dec 28, 2012
Abate by
Jan 8, 2013
Penalty
Initial $3,080 · Current $1,500 Reduced
29 CFR 1926.502(d)(16)(ii):  The personal fall arrest system did not limit the maximum arresting force on an employee to 1,800 pounds (8 kN) when used with a body harness.    Jobsite:  The personal fall arrest system, worn by the employee guiding the crane operator, did not limit the maximum arresting force on the employee to 1,800 pounds.
Recent events (3)
  • — F (O) $1500
  • — C (S) $3080
  • — Z (S) $3080

1926.502 D16 III

Other-than-serious 1 instance 1 exposed
Issued
Dec 28, 2012
Abate by
Jan 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(16)(iii):  Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:    Jobsite:  The personal fall arrest system, used by the employee acting as the crane signal person, at the edge of the roof, was not rigged to prevent him from a free fall of more than 6 feet.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1926.502 D16 V

Other-than-serious 1 instance 1 exposed
Issued
Dec 28, 2012
Abate by
Jan 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(16)(v):  Personal fall arrest systems, when stopping a fall, did not have sufficient strength to withstand twice the potential impact energy of an employee free falling a distance of 6 feet (1.8 m) or the free fall distance permitted by the system, whichever is less.    Jobsite:  The personal fall arrest system was not designed to have sufficient strength to withstand twice the impact energy of an employee free falling 25 feet.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

View Lymo Construction Company, INC.'s full OSHA safety record →