GENEVA, OH —
OSHA Inspection: ARTHUR LOUIS STEEL COMPANY, INC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ARTHUR LOUIS STEEL COMPANY, INC in 200 NORTH AVENUE, GENEVA, OH 44041 (NAICS 332313). OSHA activity number 335836789.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARTHUR LOUIS STEEL COMPANY, INC
- Site address
- 200 NORTH AVENUE
- City
- GENEVA
- State
- OH
- ZIP
- 44041
- Mailing
- PO BOX 518, ASHTABULA, OH 44005
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332313
- Employees
- 12
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.23 D01
- Issued
- Nov 20, 2012
- Abate by
- Dec 6, 2012
- Penalty
- Initial $1,785 · Current $1,785
General-duty citation text
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers was not equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section, the width of the stair to be measured clear of all obstructions except handrails: Stairs with 5 risers, leading from one side of the drill line to the other side, were not equipped with railings on both sides.
Recent events (1)
- — Z (S) $1785
1910.106 D03 I
- Issued
- Nov 20, 2012
- Abate by
- Dec 11, 2012
- Penalty
- Initial $3,570 · Current $3,570
General-duty citation text
29 CFR 1910.106(d)(3)(i): More than 60 gallons of Class I or Class II flammable liquids were stored in a storage cabinet: 120 gallons of Class 1-B flammables were stored in a job-made cabinet.
Recent events (1)
- — Z (S) $3570
1910.106 D03 II
- Issued
- Nov 20, 2012
- Abate by
- Dec 11, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(d)(3)(ii): Flammable and combustible liquid storage cabinet(s) were not labeled in conspicuous lettering, "Flammable - Keep Fire Away": The home-made flammable storage cabinet was unlabeled with the hazard warning.
Recent events (1)
- — Z (S) $0
1910.106 D03 II A
- Issued
- Nov 20, 2012
- Abate by
- Dec 11, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(d)(3)(ii)(a): Metal storage cabinets construction. The bottom, top, door, and sides of cabinet were not at least No. 18 gage sheet iron and double walled with 1 1/2 - inch air space. Joints were not riveted, welded or made tight by some equally effective means. The door was not provided with a three-point lock, and the door sill was not raised at least 2 inches above the bottom of the cabinet: The home-made cabinet was single-walled and without a three-point lock.
Recent events (1)
- — Z (S) $0
1910.147 C04 II
- Issued
- Nov 20, 2012
- Abate by
- Dec 26, 2012
- Penalty
- Initial $2,380 · Current $2,380
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy: Specific procedural steps were not developed and written for employees who perform maintenance on equipment including but not limited to the DRL drill line with tandem HEM saw operated with electric and hydraulic energies and the GEKA hydrocrop ironworker operated with electric and hydraulic energies.
Recent events (1)
- — Z (S) $2380
1910.157 G02
- Issued
- Nov 20, 2012
- Abate by
- Dec 11, 2012
- Penalty
- Initial $1,785 · Current $1,785
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: Employees expected to use ABC fire extinguishers to fight incipient fires were not provided with initial and annual fire extinguisher training. The last training was provided in 2009.
Recent events (1)
- — Z (S) $1785
1910.219 D01
- Issued
- Nov 20, 2012
- Abate by
- Dec 6, 2012
- Penalty
- Initial $1,785 · Current $1,785
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): In the drill line area, a belt and pulley that powered a stencilling wheel and located at floor level was not guarded.
Recent events (1)
- — Z (S) $1785
1910.134 C02 I
- Issued
- Nov 20, 2012
- Abate by
- Dec 1, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: Employees voluntarily using dust masks were not provided with the information in Appendix D of the respirator standard, or the equivalent information.
Recent events (1)
- — Z (O) $0
1910.134 C02 II
- Issued
- Nov 20, 2012
- Abate by
- Dec 26, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: The employer did not establish a written respiratory protection program for employees who voluntarily wore 1/2 mask negative-pressure respirators during spray painting operations.
Recent events (1)
- — Z (O) $0
1910.303 F01
- Issued
- Nov 20, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(1): Each disconnecting means required by Subpart S of Part 1910 for motors and appliances was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: At least one disconnect was observed as unlabeled, and by its location, unable to be determined as to what it powered.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 332313)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335836789.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.