Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SHANE FELTER INDUSTRIES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SHANE FELTER INDUSTRIES, INC. in 1569 PITTSBURGH ROAD, UNIONTOWN, PA 15401 (NAICS 332312). OSHA activity number 335839197.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Shane Felter Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Shane Felter Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1569 PITTSBURGH ROAD
City
UNIONTOWN
State
PA
ZIP
15401
Mailing
P.O. BOX 2022, UNIONTOWN, PA 15401
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
42
Ownership type
A

9 citations on file for this inspection.

1910.147 D04 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Dec 19, 2012
Abate by
Jan 9, 2013
Penalty
Initial $3,080 · Current $0 Reduced
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:     (a) Fabrication Bay, Marvel 25A-Band Saw: On or before September 24, 2012, an employee was exposed to laceration and/or amputation hazards in that electrical power was not isolated in the off position while changing the band saw blade.     (b) Paint Shop Bay, Wheelabrator: On or before August 20, 2012, an employee was exposed to laceration and/or amputation hazards in that electrical power was not isolated in the off position while installing previously removed guards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3080

1910.147 C05 I

Deleted Serious Gravity 1 2 instances 2 exposed
Issued
Dec 19, 2012
Abate by
Jan 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources:    (a) Fabrication Bay, Marvel 25 A - Band Saw: On or before September 24, 2012, an employee was not provided with a lock for ensuring the electrical disconnect switch remained in the off position while changing the band saw blade.     (b) Paint Shop Bay, Wheelabrator: On or before August 20, 2012, an employee was not provided with a lock for ensuring the electrical disconnect switch remained in the off position while installing previously removed guards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I A

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Dec 19, 2012
Abate by
Feb 19, 2013
Penalty
Initial $3,080 · Current $0 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:    (a) Fabrication Bay, Marvel 25 A- Band Saw: On or before September 24, 2012, an employee was permitted to change a blade without first being trained on the locations energy control program.     (b) Paint Shop Bay, Wheelabrator: On or before August 20, 2012, an employee was permitted to install previusly removed guards without first being trained on the locations energy control program.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3080

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 19, 2012
Abate by
Feb 19, 2013
Penalty
Initial $3,080 · Current $3,000 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    (a) Fabrication Bay, Marvel 25A-Band Saw: On or before August 23, 2012, an employee was exposed to laceration and/or amputation hazards in that approximately 10 inches of the blade was unguarded and not engaged with the material being cut.    (b) Paint Shop Bay Wheelabrator: On or before August 20, 2012, an employee was exposed to laceration and/or amputation hazards in that electrical power was not isolated in the off position while installing previously removed guards.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $3080

1910.219 F03

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 19, 2012
Penalty
Initial $3,080 · Current $0 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven feet or less above floors or platforms were not enclosed:     (a) Paint Shop Bay, Wheelabrator: On or before August 20, 2012, an employee was exposed to laceration and/or amputation hazards in that chain and sprocket guards were not reinstalled prior to operating the equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3080

1910.303 B02

Other-than-serious 6 instances 4 exposed
Issued
Dec 19, 2012
Abate by
Jan 2, 2013
Penalty
Initial $3,080 · Current $1,250 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:     (a) Fabrication Bay, Lincoln Welder, Serial Number: V1100705834: On or before August 20, 2012, employees were exposed to arcing part and/or electrical fire hazards in that a cable connector was used to secure a flexible cord powered at 480 Volts AC three-phase to the equipment.     (b) Fabrication Bay, Lincoln Welder, Using Wire Feeder Serial Number: 850978: On or before August 20, 2012, employees were exposed to arcing part and/or electrical fire hazards in that a cable connector was used to secure a flexible cord powered at 480 Volts AC three-phase to the equipment.     (c) Fabrication Bay, Lincoln Welder, Serial Number: V1100700093: On or before August 20, 2012, employees were exposed to arcing part and/or electrical fire hazards in that a cable connector was used to secure a flexible cord powered at 480 Volts AC three-phase to the equipment.     (d) Fabrication Bay, Lincoln Welder, Equipment Using External Ground: On or before August 20, 2012, employees were exposed to arcing part and/or electrical fire hazards in that a cable connector was used to secure a flexible cord and ground conductor powered at 480 Volts AC three-phase to the equipment.     (e) Fabrication Bay, Lincoln Welder, Serial Number: V1950310717: On or before August 20, 2012, employees were exposed to arcing part and/or electrical fire hazards in that a cable connector was used to secure a flexible cord powered at 480 Volts AC three-phase to the equipment.     (f) Fabrication Bay, Circular Sander: On or before August 20, 2012, employees were exposed to arcing part and/or electrical fire hazards in that a metallic cable connector was used to secure a flexible cord powered at 480 Volts AC three-phase to the equipment.
Recent events (2)
  • — I (O) $1250
  • — Z (S) $3080

1910.303 B07 IV

Other-than-serious 1 instance 1 exposed
Issued
Dec 19, 2012
Penalty
Initial $5,390 · Current $1,250 Reduced
29 CFR 1910.303(b)(7)(iv): There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating:    (a) Fabrication Bay, Extension Cord: On or before August 20, 2012, an employee was exposed to electrical shock and arcing part hazards in that a 120 Volt AC cord was damaged.
Recent events (2)
  • — I (O) $1250
  • — Z (S) $5390

1910.305 G02 III

Serious Gravity 5 2 instances 2 exposed
Issued
Dec 19, 2012
Abate by
Jan 2, 2013
Penalty
Initial $3,080 · Current $3,080
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    (a) Fabrication Bay, Lincoln Welder, Using Wire Feeder Serial Number: 850978: On or before August 20, 2012, employees were exposed to arcing part and/or electrical shock hazards in that a flexible cord was not secured to the equipment.      (b) Fabrication Bay, Lincoln Welder, Serial Number: V1950310717: On or before August 20, 2012, employees were exposed to arcing part and/or electrical shock hazards in that flexible cord was not secured to the equipment.
Recent events (2)
  • — I (S) $3080
  • — Z (S) $3080

5(a)(1)

Serious Gravity 5 4 instances 3 exposed
Issued
Dec 19, 2012
Abate by
Jan 16, 2013
Penalty
Initial $19,250 · Current $3,420 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees such as the employer fails to make necessary repairs, resulting in the operation of the cranes with defective or missing parts affecting the safe operation of the cranes and likely to result in serious injury or death in the event of a crane malfunction or failure:    (a) Fabrication Bay, #1 Top Running Bridge, Single Girder, Under Hung Hoist (crane serial #5409K, hoist serial #143625): On or before August 20, 2012, employees operated the crane reported deficiencies to move materials prior to evaluating the severity and making a determination if the crane was safe to use until defeciencies could be repaired:    (b) Fabrication Bay, #2 Top Running Bridge, Single Girder, Under Hung Hoist (crane serial # 5409K, hoist serial # 143628): On or before August 20, 2012, employees operated the crane with reported defeciencies could be repaired,    (c) Fabrication Bay, #3 Top Running Bridge, Single Girder, Under Hung Hoist (crane serial #5409K, hoist serial #143020): On or before August 20, 2012, employees operated the crane with reported defeciencies to move materials prior to evaluating the severity and making a determination if the cranewas safe to use unitl defeciencies could be repaired.    (d) Fabrication bay, #4 Top Running Bridge, Single Girder, Under Hung Hoist (crane serial # 5409K, hoist serial # 143623): On or before August 20, 2012, employees operated the crane with reported defeciencies to move materials prior to evaluating the severity and making a determination if the crane was safe to use unitl defeciencies could be repaired.     (1) The pendant festoon is cut, taped, and needs replaced.    (2) The trolley contactor is making excessive noise.    (3) Two collector shoe inserts are worn.     (4) There are no trolley bumpers.    (b) Fabrication Bay, #2 Top Running Bridge, Single Girder, Under Hung Hoist (crane serial #5409K, hoist serial #143628): On or before August 20, 2012, employees operated the crane with the following deficiencies and without first conducting a frequent inspection:     (1) The pendant cord pulled out of the junction box.    (2) Two collector shoe inserts are worn.    (3) The pendants strain relief is broken.    (4) The gearbox needs to be flushed out and replaced with new oil. The oil is dirty.    (5) The load brake needs to be evaluated, the customer said the hoist is dropping its load.    (6) The wire rope needs replaced. There are several broken strands.    (7) There are no trolley bumpers.    (c) Fabrication Bay, #3 Top Running Bridge, Single Girder, Under Hung Hoist (crane serial #5409K, hoist serial #143020): On or before August 20, 2012, employees operated the crane with the following deficiencies:     (1) Pendant cord is cut, spliced, taped, and needs replaced.    (2) There are no trolley bumpers.    (3) The drive chain is stretched and it doesn't appear to have any adjustment left. The pinion also slides on the shaft.     (4) The trolley gearbox leaks and needs resealed.    (d) Fabrication Bay, #4 Top Running Bridge, Single Girder, Under Hung Hoist (crane serial #5409K, hoist serial #143623): On or before August 20, 2012, employees operated the crane with the following deficiency:     (1) The trolley gearbox is leaking into the electrical cabinet and needs resealed.     The employer, Shane Felter Industries, Inc., was previously cited for a violation of this Occupational Safety and Health Administration OSH ACT of 1970 Section (5)(a)(1), which was contained in inspection #310291000, Citation #01, Item #001, issued on August 9, 2007, and became a final order on April 9, 2009, with respect to a workplace located at: 1569 Pittsburgh Road, Uniontown, Pa 15401.
Recent events (2)
  • — I (S) $3420
  • — Z (R) $19250

View Shane Felter Industries, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335839197.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.